EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Inter-rater and intra-rater reliability of isotonic exercise monitoring device for measuring active knee extension

Chonnanid Limsakul, Kiattisak Sengchuai, Rakkrit Duangsoithong, Nattha Jindapetch, Jermphiphut Jaruenpunyasak

PeerJ · 2023

DOI: 10.7717/peerj.14672 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, 2023. Verfasst von Chonnanid Limsakul und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand. Hauptthemen laut MEDLINE: Knee, Knee Joint. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Faculty of Medicine Research Foundation, Prince of Songkla University and Broadcasting and Telecommunications Research and Development Fund for Public Interest.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The goal of this study was to assess the reliability of electromyography and range of motion measurements obtained using a knee exercise monitoring system. This device was developed to collect data on knee exercise activities.

Methods

Twenty healthy individuals performed isotonic quadriceps exercises in this study. The vastus medialis surface electromyography (sEMG) and range of motion (ROM) of the knee were recorded during the exercise using the isotonic knee exercise monitoring device, the Mobi6-6b, and a video camera system. Each subject underwent a second measuring session at least 24 h after the first session. To determine reliability, the intraclass correlation coefficients (ICCs) and standard error of measurement (SEM) at the 95% confidence interval were calculated, and a Bland–Altman analysis was performed.

Results

For inter-rater reliability, the ICCs of the mean absolute value (MAV) and root mean square (RMS) of sEMG were 0.73 (0.49, 0.86) and 0.79 (0.61, 0.89), respectively. ROM had an ICC of 0.93 (0.02, 0.98). The intra-rater reliability of the MAV of the sEMG was 0.89 (0.71, 0.96) and the intra-rater reliability of RMS of the sEMG was 0.88 (0.70, 0.95). The ROM between days had an intra-rater reliability of 0.82 (0.54, 0.93). The Bland–Altman analysis demonstrated no systematic bias in the MAV and RMS of sEMG, but revealed a small, systematic bias in ROM (−0.8311 degrees).

Conclusion

For sEMG and range of motion measures, the isotonic knee exercise monitoring equipment revealed moderate to excellent inter- and intra-rater agreement. However, the confidence interval of ROM inter-rater reliability was quite large, indicating a small agreement bias; hence, the isotonic knee exercise monitor may not be suitable for measuring ROM. This isotonic knee exercise monitor could detect and collect information on a patient’s exercise activity for the benefit of healthcare providers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KneeKnee JointHumansReproducibility of ResultsRange of Motion, ArticularLower Extremity

Stichwörter der Autor:innen

Inter-rater reliabilityIntra-rater reliabilityIsotonic exercise deviceKnee extensionKnee rehabilitationRange of motionSurface electromyography

Autor:innen und Institutionen

  • Department of Rehabilitation Medicine, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand.
  • Department of Electrical Engineering, Faculty of Engineering, Prince of Songkla University, Hat Yai, Songkhla, Thailand.
  • Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand.

Förderung

  • Faculty of Medicine Research Foundation, Prince of Songkla University and Broadcasting and Telecommunications Research and Development Fund for Public Interest

Zitieren

APA

Limsakul, C., Sengchuai, K., Duangsoithong, R., Jindapetch, N., & Jaruenpunyasak, J. (2023). Inter-rater and intra-rater reliability of isotonic exercise monitoring device for measuring active knee extension. PeerJ. https://doi.org/10.7717/peerj.14672

Vancouver

Limsakul C, Sengchuai K, Duangsoithong R, Jindapetch N, Jaruenpunyasak J. Inter-rater and intra-rater reliability of isotonic exercise monitoring device for measuring active knee extension. PeerJ. 2023. doi:10.7717/peerj.14672

BibTeX
@article{Limsakul2023,
  author = {Limsakul, Chonnanid and Sengchuai, Kiattisak and Duangsoithong, Rakkrit and Jindapetch, Nattha and Jaruenpunyasak, Jermphiphut},
  title = {Inter-rater and intra-rater reliability of isotonic exercise monitoring device for measuring active knee extension},
  journal = {PeerJ},
  year = {2023},
  doi = {10.7717/peerj.14672}
}
Kostenlos starten →