EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A simple spectrophotometric evaluation method for the hydrophobic anticancer drug paclitaxel

Ken Sugo, Mitsuhiro Ebara

PeerJ Analytical Chemistry · 2020

DOI: 10.7717/peerj-achem.3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ Analytical Chemistry, 2020. Verfasst von Ken Sugo und 1 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS KAKENHI.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, we demonstrate a simple spectrophotometry approach to more accurately quantify and measure paclitaxel (PTX) concentrations. PTX cannot be precisely quantified when mixed with an aqueous solvent, and carries the risk of undergoing crystal precipitation. It is likely that PTX undergoes numerous interactions with aqueous solvents and enters a supersaturated state due to its low solubility. Therefore, a quantitative method is required to measure PTX for quality control before clinical use. Although several high-performance liquid chromatography (HPLC) methods have been reported to date, not all medical facilities have a clinical laboratory with such HPLC devices and analysis techniques. Spectroscopy is a simple and convenient method; however, calibration standards are prepared with an organic solvent, such as methanol and acetonitrile, which, when mixed with PTX, can cause solvent effects that lead to inaccurate results. We generated a calibration curve of PTX at various concentrations (40%, 50%, 60%, 70%, 80%, 90% and 100%) of methanol and evaluated the relative error from HPLC results. The optimum methanol concentration for quantification of PTX was 65.8%, which corresponded to the minimum relative error. The detection limit and quantification limit were 0.030 μg/mL and 0.092 μg/mL, respectively. It was possible to predict the PTX concentration even when polyoxyethylene castor oil and anhydrous ethanol were added, as in the commercially available PTX formulation, by diluting 32-fold with saline after mixing. Our findings show that PTX can be more accurately quantified using a calibration curve when prepared in a methanol/water mixture without the need for special devices or techniques.

Förderung

  • JSPS KAKENHI

Zitieren

APA

Sugo, K., & Ebara, M. (2020). A simple spectrophotometric evaluation method for the hydrophobic anticancer drug paclitaxel. PeerJ Analytical Chemistry. https://doi.org/10.7717/peerj-achem.3

Vancouver

Sugo K, Ebara M. A simple spectrophotometric evaluation method for the hydrophobic anticancer drug paclitaxel. PeerJ Analytical Chemistry. 2020. doi:10.7717/peerj-achem.3

BibTeX
@article{Sugo2020,
  author = {Sugo, Ken and Ebara, Mitsuhiro},
  title = {A simple spectrophotometric evaluation method for the hydrophobic anticancer drug paclitaxel},
  journal = {PeerJ Analytical Chemistry},
  year = {2020},
  doi = {10.7717/peerj-achem.3}
}
Kostenlos starten →