EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

On the mechanism of automated fizzy extraction

Chun-Ming Chang, Hao-Chun Yang, Pawel L. Urban

PeerJ Analytical Chemistry · 2019

DOI: 10.7717/peerj-achem.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ Analytical Chemistry, 2019. Verfasst von Chun-Ming Chang und 2 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fizzy extraction (FE) facilitates analysis of volatile solutes by promoting their transfer from the liquid to the gas phase. A carrier gas is dissolved in the sample under moderate pressure (Δ p ≈ 150 kPa), followed by an abrupt decompression, what leads to effervescence. The released gaseous analytes are directed to an on-line detector due to a small pressure difference. FE is advantageous in chemical analysis because the volatile species are released in a short time interval, allowing for pulsed injection, and leading to high signal-to-noise ratios. To shed light on the mechanism of FE, we have investigated various factors that could potentially contribute to the extraction efficiency, including: instrument-related factors, method-related factors, sample-related factors, and analyte-related factors. In particular, we have evaluated the properties of volatile solutes, which make them amenable to FE. The results suggest that the organic solutes may diffuse to the bubble lumen, especially in the presence of salt. The high signal intensities in FE coupled with mass spectrometry are partly due to the high sample introduction rate (upon decompression) to a mass-sensitive detector. However, the analytes with different properties (molecular weight, polarity) reveal distinct temporal profiles, pointing to the effect of bubble exposure to the sample matrix. A sufficient extraction time (~12 s) is required to extract less volatile solutes. The results presented in this report can help analysts to predict the occurrence of matrix effects when analyzing real samples. They also provide a basis for increasing extraction efficiency to detect low-abundance analytes.

Zitieren

APA

Chang, C., Yang, H., & Urban, P. L. (2019). On the mechanism of automated fizzy extraction. PeerJ Analytical Chemistry. https://doi.org/10.7717/peerj-achem.2

Vancouver

Chang C, Yang H, Urban PL. On the mechanism of automated fizzy extraction. PeerJ Analytical Chemistry. 2019. doi:10.7717/peerj-achem.2

BibTeX
@article{Chang2019,
  author = {Chang, Chun-Ming and Yang, Hao-Chun and Urban, Pawel L.},
  title = {On the mechanism of automated fizzy extraction},
  journal = {PeerJ Analytical Chemistry},
  year = {2019},
  doi = {10.7717/peerj-achem.2}
}
Kostenlos starten →