EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Unbend, correction of local beam-induced sample motion in cryo-EM images using a 3D spline model

Lingli Kong iD, Ximena Zottig iD, Johannes Elferich iD, Nikolaus Grigorieff iD

eLife · 2026

DOI: 10.7554/elife.109119 ↗

Kurz gefasst

Fachartikel in der Zeitschrift eLife, 2026. Verfasst von Lingli Kong und 3 weiteren Autor:innen. Beteiligte Einrichtung: RNA Therapeutics Institute, University of Massachusetts Chan Medical School, Worcester, United States. Hauptthemen laut MEDLINE: Cryoelectron Microscopy, Imaging, Three-Dimensional, Image Processing, Computer-Assisted. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chan Zuckerberg Initiative, Howard Hughes Medical Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The exposure of frozen biological samples to the high-energy electron beam in a cryo-electron microscope commonly leads to beam-induced sample motion and distortions. Previously, we described Unblur , software to correct for beam-induced motion based on the alignment of full frames in a movie collected during the beam exposure (Grant and Grigorieff, 2015). Here, we present Unbend , extending Unblur by accommodating more localized sample bending and distortions using a 3D cubic B-spline model. Unbend is integrated into our cis TEM software with a new local motion visualization panel. We processed movie frames from various in situ sample types, including whole cells, lamellae, and cell lysates, to analyze motion behavior across different specimen types. To quantify the improvement in high-resolution signal, we utilized the 2D template matching method to search large ribosomal subunits from the motion-corrected micrographs. Overall, the signal-to-noise ratio of detected particles improved by 3–8% across different samples compared with full-frame aligned micrographs, while the number of detected target particles increased by up to ~300%. Furthermore, we processed micrograph montages to study motion patterns across an entire sample, revealing considerable variance in distortion scale within the same sample, suggesting a complex underlying mechanism.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cryoelectron MicroscopyImaging, Three-DimensionalImage Processing, Computer-AssistedSoftwareMotionAnimals

Stichwörter der Autor:innen

candida albicanscell biologycercopithecus aethiopscryo-EMdistortion correctionimage processingmolecular biophysicsmovie alignmentmus musculusmycoplasma pneumoniaeribosomesaccharomyces cerevisiaestructural biologytwo-dimensional template matching

Autor:innen und Institutionen

  • RNA Therapeutics Institute, University of Massachusetts Chan Medical School, Worcester, United States.
  • Howard Hughes Medical Institute, University of Massachusetts Chan Medical School, Worcester, United States.

ORCID-Profile: Lingli Kong, Ximena Zottig, Johannes Elferich, Nikolaus Grigorieff

Förderung

  • Chan Zuckerberg Initiative
  • Howard Hughes Medical Institute

Zitieren

APA

Kong, L., Zottig, X., Elferich, J., & Grigorieff, N. (2026). Unbend, correction of local beam-induced sample motion in cryo-EM images using a 3D spline model. eLife. https://doi.org/10.7554/elife.109119

Vancouver

Kong L, Zottig X, Elferich J, Grigorieff N. Unbend, correction of local beam-induced sample motion in cryo-EM images using a 3D spline model. eLife. 2026. doi:10.7554/elife.109119

BibTeX
@article{Kong2026,
  author = {Kong, Lingli and Zottig, Ximena and Elferich, Johannes and Grigorieff, Nikolaus},
  title = {Unbend, correction of local beam-induced sample motion in cryo-EM images using a 3D spline model},
  journal = {eLife},
  year = {2026},
  doi = {10.7554/elife.109119}
}
Kostenlos starten →