EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantification of the effect of hemodynamic occlusion in two-photon imaging of mouse cortex

Baba Yogesh iD, Matthias Heindorf, Rebecca Jordan, Georg B Keller iD

eLife · 28.05.2025 · 14

DOI: 10.7554/elife.104914 ↗

Kurz gefasst

Fachartikel in der Zeitschrift eLife, online erschienen am 28.05.2025. Verfasst von Baba Yogesh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Friedrich Miescher Institute for Biomedical Research, Basel, Switzerland. Hauptthemen laut MEDLINE: Hemodynamics, Cerebral Cortex, Microscopy, Fluorescence, Multiphoton, Optical Imaging. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council, Swiss National Science Foundation, Novartis Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The last few years have seen an explosion in the number of tools available to measure neuronal activity using fluorescence imaging (Chen et al., 2013; Feng et al., 2019; Jing et al., 2019; Sun et al., 2018; Wan et al., 2021). When performed in vivo, these measurements are invariably contaminated by hemodynamic occlusion artifacts. In widefield calcium imaging, this problem is well recognized. For two-photon imaging, however, the effects of hemodynamic occlusion have only been sparsely characterized. Here, we perform a quantification of hemodynamic occlusion effects using measurements of fluorescence changes observed with GFP expression using both widefield and two-photon imaging in mouse cortex. We find that in many instances the magnitude of signal changes attributable to hemodynamic occlusion is comparable to that observed with activity sensors. Moreover, we find that hemodynamic occlusion effects were spatially heterogeneous, both over cortical regions and across cortical depth, and exhibited a complex relationship with behavior. Thus, hemodynamic occlusion is an important caveat to consider when analyzing and interpreting not just widefield but also two-photon imaging data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemodynamicsCerebral CortexMicroscopy, Fluorescence, MultiphotonOptical ImagingAnimalsMiceMice, Inbred C57BLNeuronsGreen Fluorescent ProteinsMale

Stichwörter der Autor:innen

GRAB sensorshemodynamic occlusionmousemouse cortexneurosciencetwo-photon imagingwidefield imaging

Substanzen

Green Fluorescent Proteins

Autor:innen und Institutionen

  • Friedrich Miescher Institute for Biomedical Research, Basel, Switzerland.
  • Faculty of Natural Sciences, University of Basel, Basel, Switzerland.
  • Simons Initiative for the Developing Brain, University of Edinburgh, Edinburgh, United Kingdom.

ORCID-Profile: Baba Yogesh, Georg B Keller

Förderung

  • European Research Council
  • Swiss National Science Foundation
  • Novartis Research Foundation

Zitieren

APA

Yogesh, B., Heindorf, M., Jordan, R., & Keller, G. B. (2025). Quantification of the effect of hemodynamic occlusion in two-photon imaging of mouse cortex. eLife, 14. https://doi.org/10.7554/elife.104914

Vancouver

Yogesh B, Heindorf M, Jordan R, Keller GB. Quantification of the effect of hemodynamic occlusion in two-photon imaging of mouse cortex. eLife. 2025;14. doi:10.7554/elife.104914

BibTeX
@article{Yogesh2025,
  author = {Yogesh, Baba and Heindorf, Matthias and Jordan, Rebecca and Keller, Georg B},
  title = {Quantification of the effect of hemodynamic occlusion in two-photon imaging of mouse cortex},
  journal = {eLife},
  year = {2025},
  volume = {14},
  doi = {10.7554/elife.104914}
}
Kostenlos starten →