Systematische Übersicht in der Zeitschrift Journal of the American Podiatric Medical Association, 2023-07. Verfasst von Young Hwan Park und 3 weiteren Autor:innen. Beteiligte Einrichtung: *Korea University Guro Hospital, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Foot, Fasciitis, Plantar. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Because ultrasound measurement of plantar fascia thickness is widely used in the diagnosis and evaluation of plantar fasciitis, it is important to understand and minimize the errors that occur with this measurement. The aim of this systematic review was to identify and synthesize studies reporting on intrarater and interrater reliability of ultrasound measurement of plantar fascia thickness.

Methods

After comprehensive searches in the MEDLINE, Embase, and Cochrane Library databases, 11 studies involving 238 healthy participants and 68 patients with pathologic foot disorders were included.

Results

Seven of 11 studies revealed a low risk of bias. Most of the studies reported good to excellent intrarater and interrater reliability for ultrasound measurement of plantar fascia thickness (intrarater intraclass correlation coefficient [ICC], 0.77–0.98; interrater ICC, 0.76–0.98). In addition, two studies on intrarater reliability and one study on interrater reliability showed moderate reliability (ICCs, 0.65, 0.67, and 0.59, respectively). Overall, the standard error of measurement was less than 5% and did not exceed 7%.

Conclusions

The findings of this review suggest that ultrasound measurement of plantar fascia thickness is reliable in terms of both relative and absolute reliability. Reliability can be optimized by using the average of multiple measurements and an experienced operator.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FootFasciitis, PlantarHumansReproducibility of ResultsUltrasonographyMuscle, SkeletalFascia

Autor:innen und Institutionen

  • *Korea University Guro Hospital, Seoul, Republic of Korea.

Zitieren

APA

Park, Y. H., Kim, H. J., Kim, W., & Choi, J. W. (2023). Reliability of Ultrasound Measurement of Plantar Fascia Thickness: A Systematic Review. Journal of the American Podiatric Medical Association, 113(4). https://doi.org/10.7547/21-024

Vancouver

Park YH, Kim HJ, Kim W, Choi JW. Reliability of Ultrasound Measurement of Plantar Fascia Thickness: A Systematic Review. Journal of the American Podiatric Medical Association. 2023;113(4). doi:10.7547/21-024

BibTeX
@article{Park2023,
  author = {Park, Young Hwan and Kim, Hak Jun and Kim, Woon and Choi, Jung Woo},
  title = {Reliability of Ultrasound Measurement of Plantar Fascia Thickness: A Systematic Review},
  journal = {Journal of the American Podiatric Medical Association},
  year = {2023},
  volume = {113},
  number = {4},
  doi = {10.7547/21-024}
}
Kostenlos starten →