Vergleichsstudie

Comparison of Biomechanical Effects of Different Configurations of Kirschner Wires on the Epiphyseal Plate and Stability in a Salter-Harris Type 2 Distal Femoral Fracture Model

Sermet Inal, Kadir Gok, Arif Gok, Ahmet Murat Pinar, Canan Inal

Journal of the American Podiatric Medical Association · 2019-01 · 109 (1) · 13-21

DOI: 10.7547/16-112 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of the American Podiatric Medical Association, 2019-01. Verfasst von Sermet Inal und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Bone Wires, Computer Simulation. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

We sought to investigate the different configurations of Kirschner wires used in distal femur Salter-Harris (SH) type 2 epiphyseal fracture for stabilization after reduction under axial, rotational, and bending forces and to define the biomechanical effects on the epiphyseal plate and the fracture line and decide which was more advantageous.

Methods

The SH type 2 fracture was modeled using design software for four different configurations: cross, cross-parallel, parallel medial, and parallel lateral with two Kirschner wires, and computer-aided numerical analyses of the different configurations after reduction were performed using the finite element method. For each configuration, the mesh process, loading condition (axial, bending, and rotational), boundary conditions, and material models were applied in finite element software, and growth cartilage and von Mises stress values occurring around the Kirschner wire groove were calculated.

Results

In growth cartilage, the stresses were highest in the parallel lateral configuration and lowest in the cross configuration. In Kirschner wires, the stresses were highest in the cross configuration and lowest in the cross-parallel and parallel lateral configurations. In the groove between the growth cartilage and the Kirschner wire interface, the stresses were highest in the parallel lateral configuration and lowest in the cross configuration.

Conclusions

The results showed that the cross configuration is advantageous in fixation. In addition, in the SH type 2 epiphyseal fracture, we believe that the fixation shape should not be applied in the lateral configuration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone WiresComputer SimulationEpiphysesFemoral FracturesFinite Element AnalysisFracture Fixation, InternalHumansStress, Mechanical

Zitieren

APA

Inal, S., Gok, K., Gok, A., Pinar, A. M., & Inal, C. (2019). Comparison of Biomechanical Effects of Different Configurations of Kirschner Wires on the Epiphyseal Plate and Stability in a Salter-Harris Type 2 Distal Femoral Fracture Model. Journal of the American Podiatric Medical Association, 109(1), 13-21. https://doi.org/10.7547/16-112

Vancouver

Inal S, Gok K, Gok A, Pinar AM, Inal C. Comparison of Biomechanical Effects of Different Configurations of Kirschner Wires on the Epiphyseal Plate and Stability in a Salter-Harris Type 2 Distal Femoral Fracture Model. Journal of the American Podiatric Medical Association. 2019;109(1):13-21. doi:10.7547/16-112

BibTeX
@article{Inal2019,
  author = {Inal, Sermet and Gok, Kadir and Gok, Arif and Pinar, Ahmet Murat and Inal, Canan},
  title = {Comparison of Biomechanical Effects of Different Configurations of Kirschner Wires on the Epiphyseal Plate and Stability in a Salter-Harris Type 2 Distal Femoral Fracture Model},
  journal = {Journal of the American Podiatric Medical Association},
  year = {2019},
  volume = {109},
  number = {1},
  pages = {13--21},
  doi = {10.7547/16-112}
}
Kostenlos starten →