EUVIMEDEUVIMED entdecken
Querschnittstudie

DIAGNOSTIC ACCURACY OF SERUM SQUAMOUS CELL CARCINOMA ANTIGEN AND CARCINOEMBRYONIC ANTIGEN IN DETECTING NON-SMALL CELL LUNG CANCER: A CROSS-SECTIONAL STUDY FROM SOKOTO, NORTHWESTERN NIGERIA

Abdullahi, Isah, Umar Abubakar, Salisu Ismail, Solomon Ifeanyi Ukwuani, Moyijo Abubakar Maishanu, Abdulaziz Muhammad, Muideen Adegbola, Alioke I., Akanni Bolaji

African Journal of Research in Medical and Health Sciences · 22.12.2025

DOI: 10.71921/ajrmhs.vol4no1.92 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift African Journal of Research in Medical and Health Sciences, erschienen am 22.12.2025. Verfasst von Abdullahi und 9 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Lung cancer is one of the leading causes of cancer incidence and cancer-related deaths globally. Late presentation, non-specific symptoms, and limited access to advanced imaging contribute to delayed diagnosis in Nigeria. Serum biomarkers such as squamous cell carcinoma antigen (SCC-Ag) and carcinoembryonic antigen (CEA) have been associated with non-small cell lung cancer (NSCLC), but their diagnostic accuracy remains uncertain.

Objective

To evaluate the diagnostic performance of serum SCC-Ag and CEA, individually and in combination, for detecting NSCLC.

Methods

This prospective cross-sectional study recruited patients with suspected primary lung cancer at Usmanu Danfodiyo University Teaching Hospital, Sokoto, from February 2022 to February 2023. All participants underwent tissue biopsy and serum assays for SCC-Ag and CEA using enzyme-linked immunosorbent assay (ELISA). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and receiver operating characteristic (ROC) curves were computed.

Results

Twenty-two patients completed the study; 16 (72.7%) had NSCLC. SCC-Ag demonstrated high sensitivity (93.8%) but low specificity (28.6%). CEA showed moderate sensitivity (50%) and specificity (42.8%). The combination of SCC-Ag and CEA achieved 100% sensitivity but only 42.9% specificity. All biomarkers had poor diagnostic accuracy, with AUC values below 0.7.

Conclusion

Although SCC-Ag and combined biomarkers showed high sensitivity, their low specificity and poor overall accuracy limit their use for NSCLC diagnosis in clinical practice. Larger studies are recommended.

Schlagwörter

non-small cell lung cancersquamous cell carcinoma antigencarcinoembryonic antigenserum tumor markersdiagnostic accuracycombined biomarkerssensitivity and specificityearly cancer detectionSokoto, Nigeria

Zitieren

APA

Abdullahi, Isah, Abubakar, U., Ismail, S., Ukwuani, S. I., Maishanu, M. A., Muhammad, A., Adegbola, M., I., A., & Bolaji, A. (2025). DIAGNOSTIC ACCURACY OF SERUM SQUAMOUS CELL CARCINOMA ANTIGEN AND CARCINOEMBRYONIC ANTIGEN IN DETECTING NON-SMALL CELL LUNG CANCER: A CROSS-SECTIONAL STUDY FROM SOKOTO, NORTHWESTERN NIGERIA. African Journal of Research in Medical and Health Sciences. https://doi.org/10.71921/ajrmhs.vol4no1.92

Vancouver

Abdullahi, Isah, Abubakar U, Ismail S, Ukwuani SI, Maishanu MA, et al. DIAGNOSTIC ACCURACY OF SERUM SQUAMOUS CELL CARCINOMA ANTIGEN AND CARCINOEMBRYONIC ANTIGEN IN DETECTING NON-SMALL CELL LUNG CANCER: A CROSS-SECTIONAL STUDY FROM SOKOTO, NORTHWESTERN NIGERIA. African Journal of Research in Medical and Health Sciences. 2025. doi:10.71921/ajrmhs.vol4no1.92

BibTeX
@article{Abdullahi2025,
  author = {Abdullahi and Isah and Abubakar, Umar and Ismail, Salisu and Ukwuani, Solomon Ifeanyi and Maishanu, Moyijo Abubakar and Muhammad, Abdulaziz and Adegbola, Muideen and I., Alioke and Bolaji, Akanni},
  title = {DIAGNOSTIC ACCURACY OF SERUM SQUAMOUS CELL CARCINOMA ANTIGEN AND CARCINOEMBRYONIC ANTIGEN IN DETECTING NON-SMALL CELL LUNG CANCER: A CROSS-SECTIONAL STUDY FROM SOKOTO, NORTHWESTERN NIGERIA},
  journal = {African Journal of Research in Medical and Health Sciences},
  year = {2025},
  doi = {10.71921/ajrmhs.vol4no1.92}
}
Kostenlos starten →