EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Evaluation of the accuracy of a custom-made plate in maxillary repositioning

Wafaa A Mohamed, Susan A Hassan, Fatma I Mohamed, Ahmed A Barakat, Hatem H Alahmady, Mahmoud M Fata, Ahmed A Mohamed

Archives of Craniofacial Surgery · 20.06.2026 · 27 (3) · 120-128

DOI: 10.7181/acfs.2025.0040 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Craniofacial Surgery, erschienen am 20.06.2026. Verfasst von Wafaa A Mohamed und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine for Girls, Al-Azhar University, Cairo, Egypt. wafaaanwar89@yahoo.com. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Orthognathic surgery has become increasingly accurate with the integration of computerized technologies. This study aimed to evaluate the accuracy of custom-made plates in transferring the three-dimensional virtual plan to intraoperative maxillary repositioning.

Methods

This study included 10 patients. A digital surgical simulation technique was used for preoperative planning. The surgical components—osteotomy/plates, locating guides, and customized titanium plates—were fabricated using computer-aided design and manufacturing techniques, replacing the need for a surgical splint. Postoperative outcomes were assessed using unaltered anatomical landmarks from the preoperative virtual plan. Absolute discrepancies in translational and rotational movements between the planned and actual postoperative positions were measured through superimposition analysis. This evaluation assessed the precision of custom-made plates in transferring the virtual surgical plan, identifying deviations in the cephalocaudal, mediolateral, and anteroposterior directions that could influence functional and esthetic outcomes.

Results

No statistically significant differences were observed for any landmarks across the axial, coronal, and sagittal planes. The greatest variability was noted at the posterior nasal spine landmark in the axial plane (1.7 mm), compared with the coronal (0.9 mm) and sagittal (0.5 mm) planes.

Conclusion

Customized titanium plates effectively transferred the virtual surgical plan for maxillary repositioning without the need for an occlusal splint. However, potential posterior interference should be considered during surgical execution.

Schlagwörter

Stichwörter der Autor:innen

Computer-aided designData accuracyDental implantsOrthognathic surgery

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine for Girls, Al-Azhar University, Cairo, Egypt. wafaaanwar89@yahoo.com.
  • Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine for Girls, Al-Azhar University, Cairo, Egypt.
  • Department of Oral and Maxillofacial Surgery, Deraya University, New Minia, Egypt.
  • Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Future University, New Cairo, Egypt.
  • Sharq El Madina Hospital, Alexandria, Egypt.
  • Department of Orthodontics, Faculty of Dental Medicine, Menoufia University, Shebin El-Kom, Egypt.

Zitieren

APA

Mohamed, W. A., Hassan, S. A., Mohamed, F. I., Barakat, A. A., Alahmady, H. H., Fata, M. M., & Mohamed, A. A. (2026). Evaluation of the accuracy of a custom-made plate in maxillary repositioning. Archives of Craniofacial Surgery, 27(3), 120-128. https://doi.org/10.7181/acfs.2025.0040

Vancouver

Mohamed WA, Hassan SA, Mohamed FI, Barakat AA, Alahmady HH, Fata MM, et al. Evaluation of the accuracy of a custom-made plate in maxillary repositioning. Archives of Craniofacial Surgery. 2026;27(3):120-128. doi:10.7181/acfs.2025.0040

BibTeX
@article{Mohamed2026,
  author = {Mohamed, Wafaa A and Hassan, Susan A and Mohamed, Fatma I and Barakat, Ahmed A and Alahmady, Hatem H and Fata, Mahmoud M and Mohamed, Ahmed A},
  title = {Evaluation of the accuracy of a custom-made plate in maxillary repositioning},
  journal = {Archives of Craniofacial Surgery},
  year = {2026},
  volume = {27},
  number = {3},
  pages = {120--128},
  doi = {10.7181/acfs.2025.0040}
}
Kostenlos starten →