Hypereosinophilia-associated acute intradialytic hypotension: a case report
Kosin Medical Journal · 30.06.2026 · 41 (2) · 175-179
DOI: 10.7180/kmj.25.137 ↗Kurz gefasst
Fallbericht in der Zeitschrift Kosin Medical Journal, erschienen am 30.06.2026. Verfasst von Ji Hyun Jeon und 1 weiteren Autor:innen. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Pusan National University.
Abstract (Originalsprache)
Eosinophilia in patients undergoing hemodialysis (HD) is rare but can cause severe complications including intradialytic hypotension. Hypereosinophilia-associated acute intradialytic hypotension (HAIDH) typically develops within minutes of HD initiation and does not respond to changes in the dialyzer or dialysate. In this report, we describe a case of HAIDH associated with idiopathic hypereosinophilic syndrome that was successfully managed with corticosteroids, and we review previously reported cases.
Förderung
- Pusan National University
Zitieren
APA
Jeon, J. H., & Song, S. H. (2026). Hypereosinophilia-associated acute intradialytic hypotension: a case report. Kosin Medical Journal, 41(2), 175-179. https://doi.org/10.7180/kmj.25.137
Vancouver
Jeon JH, Song SH. Hypereosinophilia-associated acute intradialytic hypotension: a case report. Kosin Medical Journal. 2026;41(2):175-179. doi:10.7180/kmj.25.137