The role of combined multichannel intraluminal impedance and pH-monitoring in newborn with gastroesophageal reflux disease
Reviews in Health Care · 2010
DOI: 10.7175/rhc.v1i1.16 ↗Kurz gefasst
Fachartikel in der Zeitschrift Reviews in Health Care, 2010. Verfasst von Francesco Cresi und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Gastroesophageal reflux disease (GERD) is a relevant problem in first months of life and its early diagnosis and its appropriate therapy represent a real challenge for neonatologists.Multichannel Intraluminal Impedance associated with esophageal pH-monitoring (MII/pH) has been recently introduced to study GERD in infants. This technique, which is safe and with a good compliance, presents an elevated accuracy in identifying refluxes independently from their pH. The main aim of this review is to analyse data in literature on the use of MII/pH in neonates.We have considered recent studies published in PubMed in which MII is used in neonates and infants with GER: 26 studies focus on GER physiopathology and on the advantages of using MII in addition to pH-monitoring, 13 on symptoms associated with refluxes (in particular cardio-respiratory events and apnoeas) and 13 on therapy (5 on body position, 3 on thickened formulas, 1 on fortified milk and 4 on drugs).We underline the role of MII/pH in studying GERD in neonates, in which non acid-refluxes result prevalent, because of the buffering effects of milk, and in which the majority of symptoms arerelated to non-acid or weakly-acid GER. MII/pH can be considered a good technique even in the evaluation of the temporal relation between refluxes and symptoms and in the analysis of the benefits obtained by pharmacological and non-pharmacological therapy.The increasing application of MII/pH can help neonatologists to comprehend GER physiopathology, to diagnose GER and GERD and to treat better its symptoms in first months of life.
Zitieren
APA
Cresi, F., & Locatelli, E. (2010). The role of combined multichannel intraluminal impedance and pH-monitoring in newborn with gastroesophageal reflux disease. Reviews in Health Care. https://doi.org/10.7175/rhc.v1i1.16
Vancouver
Cresi F, Locatelli E. The role of combined multichannel intraluminal impedance and pH-monitoring in newborn with gastroesophageal reflux disease. Reviews in Health Care. 2010. doi:10.7175/rhc.v1i1.16
BibTeX
@article{Cresi2010,
author = {Cresi, Francesco and Locatelli, Emanuela},
title = {The role of combined multichannel intraluminal impedance and pH-monitoring in newborn with gastroesophageal reflux disease},
journal = {Reviews in Health Care},
year = {2010},
doi = {10.7175/rhc.v1i1.16}
}
EUVIMED