The Venous Excess Ultrasound Grading System in the Management of Hospitalized Patients with Hyponatremia: A Diagnostic Study
Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · 22.10.2025
DOI: 10.71749/pkj.118 ↗Kurz gefasst
Fachartikel in der Zeitschrift Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT), erschienen am 22.10.2025. Verfasst von Marques-Ortega und 19 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Hyponatremia is the most common electrolyte disorder in hospitalized patients and requires accurate assessment of volume status to guide appropriate management. The venous excess ultrasound grading system (VExUS) is a point‑of‑care ultrasound tool used to assess venous congestion through Doppler evaluation of abdominal venous flow patterns. Its role in the context of hypoosmolar hyponatremia remains to be defined.
Methods
In this proof‑of‑concept, prospective, observational study, hospitalized adult patients with hypoosmolar hyponatremia (plasma sodium ≤130 mEq/L) were included. Within 24 hours of enrolment, all patients underwent VExUS assessment evaluating the inferior vena cava diameter and Doppler waveforms in at least one venous territory (hepatic, portal, or renal veins). Treating physicians were blinded to ultrasound findings. Serum sodium was measured at baseline and at 24, 48, and 96 hours. VExUS evaluation of volume status was compared to final diagnosis and other surrogates of volume.
Results
A total of 26 patients were included. VExUS identified venous congestion in 4 patients (15.4%). VExUS discrepancies between clinical and ultrasound‑based volume assessment were observed in 2 cases (7.7%). These discrepancies were not associated with significant differences in sodium level trends (0h: p=0.409; 24h: p=0.884; 48h: p=0.598; 96h: p=0.351), nor with changes in treatment. However, VExUS eliminated discrepancies between final diagnosis and presumptive diagnosis at study inclusion.
Conclusion
In this study, VExUS proved useful in detecting venous congestion not evident on clinical examination, improving diagnostic accuracy.
Schlagwörter
Zitieren
APA
Marques-Ortega, J., F., Viejo-Boyano, Iris, González-Calero, Pablo, Ferri-Cortés, Anna, Gavilà-Chornet, Manel, Mompó-Ramos, Mar, Barrios-Carmona, Paula, Cholbi-Vives, Ester, Peris-Fernandez, María, Hernández-Jaras, & Julio (2025). The Venous Excess Ultrasound Grading System in the Management of Hospitalized Patients with Hyponatremia: A Diagnostic Study. Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT). https://doi.org/10.71749/pkj.118
Vancouver
Marques-Ortega, J. F, Viejo-Boyano, Iris, González-Calero, Pablo, et al. The Venous Excess Ultrasound Grading System in the Management of Hospitalized Patients with Hyponatremia: A Diagnostic Study. Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT). 2025. doi:10.71749/pkj.118
BibTeX
@article{MarquesOrtega2025,
author = {Marques-Ortega and J., Francisco and Viejo-Boyano and Iris and González-Calero and Pablo and Ferri-Cortés and Anna and Gavilà-Chornet and Manel and Mompó-Ramos and Mar and Barrios-Carmona and Paula and Cholbi-Vives and Ester and Peris-Fernandez and María and Hernández-Jaras and Julio},
title = {The Venous Excess Ultrasound Grading System in the Management of Hospitalized Patients with Hyponatremia: A Diagnostic Study},
journal = {Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)},
year = {2025},
doi = {10.71749/pkj.118}
}
EUVIMED