Kaji performa mesin refrigerasi siklus kompresi uap dengan refrigeran R134a dan refrigeran hidrokarbon sebagai drop-in substitute pada dengan alat ekspansi berbeda

Azridjal Aziz, Iqbal Parija, Rahmat Iman Mainil

Proceeding SNTTM BKS-TM Indonesia · 09.03.2026 · 23 (1) · 178-183

DOI: 10.71452/d8day211 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceeding SNTTM BKS-TM Indonesia, online erschienen am 09.03.2026. Verfasst von Azridjal Aziz und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Refrigerant is an essential working fluid in refrigeration system. However, the use of synthetic refrigerant such as R-134a is now restricted due to its high Global Warming Potential (GWP) value. As an alternative, MC-134 as hydrocarbon refrigerant offers more environmentally friendly solution. This research aims to compare the performance of R-134a and MC-134 in a vapor compression refrigeration cycle system, as well as analyze the influence of expansion devices, namely capillary pipes and Thermostatic Expansion Valves (TEV). The test results show that for R-134a, increasing the length of the capillary pipe, increases the Coefficient of Performance (COP) by 20.83% due to decrease in compression work. In contrast, for MC-134, there is decrease in COP by 3.35%. TEV provides the best performance with an increase in refrigeration effect of 6.05% and COP of 25.07%. However, TEV is not suitable for MC-134 because the low condensing pressure inhibits the phase change to liquid. In the use of 1.25 m and 1.5 m capillary pipes, MC-134 even has a higher COP of up to 16.65% compared to R-134a. Despite this, MC-134 still shows potential as a replacement for R-134a, with 30% of the mass capable of producing twice the refrigeration effect and 7.52% lower electric current consumption.

Zitieren

APA

Aziz, A., Parija, I., & Mainil, R. I. (2026). Kaji performa mesin refrigerasi siklus kompresi uap dengan refrigeran R134a dan refrigeran hidrokarbon sebagai drop-in substitute pada dengan alat ekspansi berbeda. Proceeding SNTTM BKS-TM Indonesia, 23(1), 178-183. https://doi.org/10.71452/d8day211

Vancouver

Aziz A, Parija I, Mainil RI. Kaji performa mesin refrigerasi siklus kompresi uap dengan refrigeran R134a dan refrigeran hidrokarbon sebagai drop-in substitute pada dengan alat ekspansi berbeda. Proceeding SNTTM BKS-TM Indonesia. 2026;23(1):178-183. doi:10.71452/d8day211

BibTeX
@article{Aziz2026,
  author = {Aziz, Azridjal and Parija, Iqbal and Mainil, Rahmat Iman},
  title = {Kaji performa mesin refrigerasi siklus kompresi uap dengan refrigeran R134a dan refrigeran hidrokarbon sebagai drop-in substitute pada dengan alat ekspansi berbeda},
  journal = {Proceeding SNTTM BKS-TM Indonesia},
  year = {2026},
  volume = {23},
  number = {1},
  pages = {178--183},
  doi = {10.71452/d8day211}
}
Kostenlos starten →