Coolant-Inventory-Constrained Flow Selection for Direct-to-Package Microfluidic Cooling in High-Heat-Flux Power Electronics
ThyssenKrupp techforum · 22.06.2026 · 2026 · 32-53
DOI: 10.71448/tk202622 ↗Kurz gefasst
Fachartikel in der Zeitschrift ThyssenKrupp techforum, online erschienen am 22.06.2026. Verfasst von Joseph Bentsman.
Abstract (Originalsprache)
Shortening the thermal path between the semiconductor junction and the working liquid through direct-to-package microfluidic cooling leads to higher heat-load capacity. This study investigates which among the five states of cooling should be chosen based on maximum heat-load capacity, junction-to-ambient thermal resistance, coolant economy, marginal flow return, and resistance partitioning when all parameters are considered under the same constraint of maximum junction temperature. The five-state matrix consists of ambient convection, detached liquid heat sink, and direct-to-package microfluidic cooling with 0.10 mL/s, 0.15 mL/s, and 0.20 mL/s flows. From there, heat flux, conductance, power lift, resistance reduction factor, coolant economy ratio, resistance-corrected merit, resistance partitioning, preference index, and load-dependent choice criteria are calculated. The 0.20 mL/s state provides the strongest absolute performance with support for 41 W, approximately 641 W cm−2, 6.72 K W−1, and 17672 W m−2 K−1. When coolant economy is considered based on inventory inside the package, the 0.10 mL/s state becomes the optimal choice, reaching approximately 578 W cm−2 while consuming only 2 mL of coolant. It also gives the highest resistance-corrected merit value. The 0.15 mL/s state only adds 1 W with minimal reduction in thermal resistance. In contrast, the second flow increase to 0.20 mL/s offers more significant improvement. Partitioning of resistances indicates that 80 % to 82 % of total resistance comes from the effective convective/spreading term, prioritizing effective wetting area and flow rate over package stack thermal conductance. The decision boundary occurs at λ ≈ 0.486 which separates peak-performance regime and coolant-economy regime. The result shows that optimal flow choice must be determined by load conditions; lower flow for efficient steady-state operation, higher flow for peak thermal loads, and mid flow only for transitional cases.
Zitieren
APA
Bentsman, J. (2026). Coolant-Inventory-Constrained Flow Selection for Direct-to-Package Microfluidic Cooling in High-Heat-Flux Power Electronics. ThyssenKrupp techforum, 2026, 32-53. https://doi.org/10.71448/tk202622
Vancouver
Bentsman J. Coolant-Inventory-Constrained Flow Selection for Direct-to-Package Microfluidic Cooling in High-Heat-Flux Power Electronics. ThyssenKrupp techforum. 2026;2026:32-53. doi:10.71448/tk202622
BibTeX
@article{Bentsman2026,
author = {Bentsman, Joseph},
title = {Coolant-Inventory-Constrained Flow Selection for Direct-to-Package Microfluidic Cooling in High-Heat-Flux Power Electronics},
journal = {ThyssenKrupp techforum},
year = {2026},
volume = {2026},
pages = {32--53},
doi = {10.71448/tk202622}
}