Research on the Impact of PiCCO-guided Precise Fluid Resuscitation on Hemodynamics and Organ Perfusion in Patients with Extremely Severe BurnsResearch Article
Life Conflux · 2024
DOI: 10.71321/7gk65202 ↗Kurz gefasst
Fachartikel in der Zeitschrift Life Conflux, 2024. Verfasst von Lulu Jiang und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Reanimation
Abstract (Originalsprache)
Objective
To explore the impact of Pulse Indicator Continuous Cardiac Output (PiCCO) on hemodynamics and organ perfusion during fluid resuscitation in patients with extremely severe burns.
Methods
This study adopted a retrospective cohort study design. A total of 32 patients with extremely severe burns admitted to the Burn Department of the First Affiliated Hospital of Anhui Medical University from June 2022 to July 2024 were included. According to the monitoring methods, they were divided into a conventional monitoring group ( n = 17 ) and a PiCCO group ( n = 15 ). The basic data, fluid replacement indicators (total fluid replacement volume, urine output, fluid replacement coefficient, urine output per hour per kilogram of body weight), hemodynamic parameters [mean arterial pressure (MAP), central venous pressure (CVP), heart rate (HR), cardiac index (CI), cardiac output (CO), systemic vascular resistance index (SVRI), extravascular lung water index (EVLWI), global end-diastolic volume index (GEDVI), intrathoracic blood volume index (ITBVI)], laboratory indicators [lactate (Lac), base excess (BE), creatine kinase (CK), creatine kinase - MB (CK - MB), alanine aminotransferase (ALT), aspartate aminotransferase (AST), blood urea nitrogen (BUN), serum creatinine (Scr)] and clinical outcomes (complication incidence, 30 - day mortality, antibiotic use time, hospital stay and cost) of the two groups were compared. T-test, repeated-measures analysis of variance, Mann-Whitney U test, Bonferroni correction, chi-square test, and Fisher's exact probability method were used for statistical analysis.
Results
A comparison of the relevant indicators of patients with extremely severe burns between the PiCCO monitoring group and the conventional monitoring group showed no difference in the general conditions between the two groups ( P>0.05 ). The total fluid replacement volume in the PiCCO monitoring group was higher in the first, second, and third 24h periods after injury ( P
Zitieren
APA
Jiang, L., Zhang, Z., Wu, Y., Yu, Y., Hu, Y., & Hu, D. (2024). Research on the Impact of PiCCO-guided Precise Fluid Resuscitation on Hemodynamics and Organ Perfusion in Patients with Extremely Severe BurnsResearch Article. Life Conflux. https://doi.org/10.71321/7gk65202
Vancouver
Jiang L, Zhang Z, Wu Y, Yu Y, Hu Y, Hu D. Research on the Impact of PiCCO-guided Precise Fluid Resuscitation on Hemodynamics and Organ Perfusion in Patients with Extremely Severe BurnsResearch Article. Life Conflux. 2024. doi:10.71321/7gk65202
BibTeX
@article{Jiang2024,
author = {Jiang, Lulu and Zhang, Zijian and Wu, Yindong and Yu, Youxin and Hu, Yi and Hu, Delin},
title = {Research on the Impact of PiCCO-guided Precise Fluid Resuscitation on Hemodynamics and Organ Perfusion in Patients with Extremely Severe BurnsResearch Article},
journal = {Life Conflux},
year = {2024},
doi = {10.71321/7gk65202}
}
EUVIMED