Comparison of the laryngeal mask airway ProSeal with the laryngeal mask airway supreme for ease of insertion and hemodynamic effects in adult patients undergoing surgery under general anesthesia
Asian Journal of Medical Sciences · 01.06.2026 · 17 (6) · 3-9
DOI: 10.71152/ajms.v17i6.5311 ↗Kurz gefasst
Fachartikel in der Zeitschrift Asian Journal of Medical Sciences, online erschienen am 01.06.2026. Verfasst von Mehwish Farooque und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Supraglottic airway devices (SADs) are widely used during general anesthesia due to their ease of insertion and minimal hemodynamic disturbances. Among second-generation devices, the ProSeal laryngeal mask airway (PLMA) and supreme laryngeal mask airway (SLMA) are commonly used, but comparative evaluation of their clinical performance remains essential. Aims and Objectives: To compare PLMA and SLMA in adult patients undergoing general anesthesia with respect to ease of insertion, number of attempts, and insertion time, while also evaluating associated hemodynamic responses, including heart rate (HR), blood pressure, and oxygen saturation (SpO2) during perioperative airway management. Materials and Methods: This prospective randomized comparative study included 140 adult patients (American Society of Anesthesiologists I–II) undergoing elective surgical procedures. Patients were allocated into two groups: Group P (PLMA) and Group S (SLMA), with 70 patients each. Parameters assessed included ease of insertion, number of attempts, time taken for successful placement, and hemodynamic variables (HR, blood pressure, and SpO2) at predefined intervals. Statistical analysis was performed with P0.05). The SLMA group demonstrated significantly shorter insertion time (3.43±1.15 vs. 6.00±2.12 s, P=0.001), higher first-attempt success rate (92.9% vs. 70.0%, P=0.001), and better ease of insertion (100% vs. 94.3%, P=0.042) compared to the PLMA group.
Conclusion
Both PLMA and SLMA provided effective airway management with comparable hemodynamic responses. However, SLMA demonstrated superior performance in terms of ease of insertion, higher first-attempt success rate, and shorter insertion time, making it a preferable SAD for elective surgical procedures under general anesthesia.
Zitieren
APA
Farooque, M., Jehangir, M., Mir, A. S., Farooque, M., Jan, M. Z., & Mir, A. H. (2026). Comparison of the laryngeal mask airway ProSeal with the laryngeal mask airway supreme for ease of insertion and hemodynamic effects in adult patients undergoing surgery under general anesthesia. Asian Journal of Medical Sciences, 17(6), 3-9. https://doi.org/10.71152/ajms.v17i6.5311
Vancouver
Farooque M, Jehangir M, Mir AS, Farooque M, Jan MZ, Mir AH. Comparison of the laryngeal mask airway ProSeal with the laryngeal mask airway supreme for ease of insertion and hemodynamic effects in adult patients undergoing surgery under general anesthesia. Asian Journal of Medical Sciences. 2026;17(6):3-9. doi:10.71152/ajms.v17i6.5311
BibTeX
@article{Farooque2026,
author = {Farooque, Mehwish and Jehangir, Majid and Mir, Aaqib Suhail and Farooque, Mohsin and Jan, Mohammad Zubair and Mir, Altaf Hussain},
title = {Comparison of the laryngeal mask airway ProSeal with the laryngeal mask airway supreme for ease of insertion and hemodynamic effects in adult patients undergoing surgery under general anesthesia},
journal = {Asian Journal of Medical Sciences},
year = {2026},
volume = {17},
number = {6},
pages = {3--9},
doi = {10.71152/ajms.v17i6.5311}
}