EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluación comparativa entre el método de Wintrobe y el sistema automatizado Alifax® para la determinación de la velocidad de Sedimentación Globular

Alfredo Ibarra-Sánchez, Claudia Soto-Félix, Anaid Guzmán-Mendoza, Leticia Cano-Barraza, Delia Barraza-Sámano

Multidisciplinary Journal of Sciences, Discoveries, and Society · 2025

DOI: 10.71068/52yb8j78 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Multidisciplinary Journal of Sciences, Discoveries, and Society, 2025. Verfasst von Alfredo Ibarra-Sánchez und 4 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The erythrocyte sedimentation rate (ESR) was a widely used hematological test that served as a nonspecific marker of inflammation. Despite the development of more specific techniques, its simplicity, low cost, and clinical value in the appropriate context maintained its relevance in medical practice. This article addressed the principles, advantages, and technical considerations of two methods used for ESR measurement: the manual Wintrobe method and the automated Alifax® system. The Wintrobe method, although less sensitive than the Westergren method, allowed ESR determination without sample dilution and with a smaller blood volume, making it useful in low- resource settings or for special populations. In contrast, Alifax® used automated capillary photometry technology, providing results equivalent to the reference method in just 20 seconds, with high reproducibility and operational efficiency. A key aspect of this study was the discussion of reference values, which should not have been considered interchangeable across methods. While Wintrobe tended to underestimate ESR in cases of active inflammation, Alifax® adopted the reference ranges of the Westergren method, for which it had been calibrated. Therefore, the need to establish and validate method-specific reference values for each population was emphasized. This study established specific reference intervals for ESR, stratified by sex, age, and analytical method, in accordance with the guidelines of CLSI EP28-A3c. The results showed consistent differences between the manual Wintrobe method and the automated Alifax® system, highlighting the importance of not interpreting their results interchangeably. Thus, it was essential for each laboratory to validate its own reference intervals to ensure accurate and clinically meaningful diagnostic interpretation. This work underscored the importance of selecting the most appropriate method for each clinical setting, considering both patient characteristics and laboratory capabilities, to ensure proper interpretation and effective integration of ESR in medical decision-making.

Zitieren

APA

Ibarra-Sánchez, A., Soto-Félix, C., Guzmán-Mendoza, A., Cano-Barraza, L., & Barraza-Sámano, D. (2025). Evaluación comparativa entre el método de Wintrobe y el sistema automatizado Alifax® para la determinación de la velocidad de Sedimentación Globular. Multidisciplinary Journal of Sciences, Discoveries, and Society. https://doi.org/10.71068/52yb8j78

Vancouver

Ibarra-Sánchez A, Soto-Félix C, Guzmán-Mendoza A, Cano-Barraza L, Barraza-Sámano D. Evaluación comparativa entre el método de Wintrobe y el sistema automatizado Alifax® para la determinación de la velocidad de Sedimentación Globular. Multidisciplinary Journal of Sciences, Discoveries, and Society. 2025. doi:10.71068/52yb8j78

BibTeX
@article{IbarraSnchez2025,
  author = {Ibarra-Sánchez, Alfredo and Soto-Félix, Claudia and Guzmán-Mendoza, Anaid and Cano-Barraza, Leticia and Barraza-Sámano, Delia},
  title = {Evaluación comparativa entre el método de Wintrobe y el sistema automatizado Alifax® para la determinación de la velocidad de Sedimentación Globular},
  journal = {Multidisciplinary Journal of Sciences, Discoveries, and Society},
  year = {2025},
  doi = {10.71068/52yb8j78}
}
Kostenlos starten →