EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Numerical Optimization of Thermoelectric Heat Pump Assisted Drying System

Amir Azirul, Adnan Ibrahim, Nurul Syakirah Nazri, Hasila Jarimi, Muhammad Ammirrul Atiqi Mohd Zainuri, Ubaidah Syafiq

Journal of Climate Change · 31.03.2025 · 11 (1) · 21

DOI: 10.70917/jcc-2025-003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Climate Change, online erschienen am 31.03.2025. Verfasst von Amir Azirul und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

One of the methods for food preservation involves utilizing the heat from solar radiation to remove moisture, aptly known as solar drying. Different approaches in enhancing solar dryer efficiency have been made throughout the years, involving circulation refinements, mechanism improvements, and insulation enhancements. Thermoelectric heat pumps (TEHP) leverage the Peltier effect to generate temperature difference that can be integrated with solar dryer system. However, the information on design and parameters for integration is scarce and underexplored. In this work, TEHP-assisted solar drying system was designed and the ideal parameters for efficient drying rate were determined by optimizing fan position and airflow rate. The system’s performance was gauged through moisture content reduction of drying loads (ginger). CFD numerical optimization was performed at the airflow rate between 0.003 - 0.012 m3/s, at three different fan locations. Results showed that lower airflow rate increases the accumulated heat inside the chamber, resulting in higher moisture content removal within the load, thus increasing drying rate. Even though the higher airflow showed greater reduction in H2O mass, reduction of drying chamber temperature was also observed, resulting in reduced effectiveness in moisture removal. The ideal fan position and airflow rate were determined to be at the system inlet (Fan 1) and 0.012 m3/s, respectively. The results from this work show the importance of fan position and airflow rate on a TEHP-assisted solar dryer towards its the drying rate to achieve a balance between energy consumption and effective drying.

Zitieren

APA

Azirul, A., Ibrahim, A., Nazri, N. S., Jarimi, H., Zainuri, M. A. A. M., & Syafiq, U. (2025). Numerical Optimization of Thermoelectric Heat Pump Assisted Drying System. Journal of Climate Change, 11(1), 21. https://doi.org/10.70917/jcc-2025-003

Vancouver

Azirul A, Ibrahim A, Nazri NS, Jarimi H, Zainuri MAAM, Syafiq U. Numerical Optimization of Thermoelectric Heat Pump Assisted Drying System. Journal of Climate Change. 2025;11(1):21. doi:10.70917/jcc-2025-003

BibTeX
@article{Azirul2025,
  author = {Azirul, Amir and Ibrahim, Adnan and Nazri, Nurul Syakirah and Jarimi, Hasila and Zainuri, Muhammad Ammirrul Atiqi Mohd and Syafiq, Ubaidah},
  title = {Numerical Optimization of Thermoelectric Heat Pump Assisted Drying System},
  journal = {Journal of Climate Change},
  year = {2025},
  volume = {11},
  number = {1},
  pages = {21},
  doi = {10.70917/jcc-2025-003}
}
Kostenlos starten →