Subscapularis Tendon Repair Improves Functional Internal Rotation after Onlay Design Reverse Shoulder Arthroplasty
The Hive - Musculoskeletal Journal · 17.01.2025 · 1 (1)
DOI: 10.70885/hmsj.2025.01.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Hive - Musculoskeletal Journal, online erschienen am 17.01.2025. Verfasst von Felipe Lacerda und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Background
A major challenge of the reverse shoulder arthroplasty (RSA) is to restore postoperative range of motion, especially internal and external rotation. Attempting to address this issue, several modifications to the prosthesis design have been made.
Purpose
This study aimed to compare functional internal rotation (fIR) outcomes following RSA with different humeral implant designs.
Methods
We conducted a retrospective comparative analysis of data from 384 patients, each with a minimum of two years of follow-up, who underwent RSA with two distinct implant models: an inlay 155° neck-shaft angle and an onlay 145° neck-shaft angle. We assessed the postoperative progress of fIR based on type I IR (with the hand blocked against the buttock), type II IR (involving lumbar sliding), and type III IR (characterized by smooth motion). We categorized type I as non-fIR, while types II and III were considered as fIR. To analyze the influence of subscapularis repair on fRI, both groups were further categorized into two subgroups: those with repaired subscapularis (subgroup R) and those without repaired subscapularis (subgroup NR).
Results
No statistically significant difference was observed when comparing postoperative fIR between the two groups. Within the entire cohort, patients in subgroup R exhibited superior fIR outcomes compared to subgroup NR (40% type III vs. 19% type III, respectively; p
Zitieren
APA
Lacerda, F., Lädermann, A., Adam, M. F., Delarue, A., Daniel, C., & Collin, P. (2025). Subscapularis Tendon Repair Improves Functional Internal Rotation after Onlay Design Reverse Shoulder Arthroplasty. The Hive - Musculoskeletal Journal, 1(1). https://doi.org/10.70885/hmsj.2025.01.002
Vancouver
Lacerda F, Lädermann A, Adam MF, Delarue A, Daniel C, Collin P. Subscapularis Tendon Repair Improves Functional Internal Rotation after Onlay Design Reverse Shoulder Arthroplasty. The Hive - Musculoskeletal Journal. 2025;1(1). doi:10.70885/hmsj.2025.01.002
BibTeX
@article{Lacerda2025,
author = {Lacerda, Felipe and Lädermann, Alexandre and Adam, Mahmoud Faisal and Delarue, Angélique and Daniel, Céline and Collin, Philippe},
title = {Subscapularis Tendon Repair Improves Functional Internal Rotation after Onlay Design Reverse Shoulder Arthroplasty},
journal = {The Hive - Musculoskeletal Journal},
year = {2025},
volume = {1},
number = {1},
doi = {10.70885/hmsj.2025.01.002}
}
EUVIMED