EUVIMEDEUVIMED entdecken
Crossref

Subscapularis Tendon Repair Improves Functional Internal Rotation after Onlay Design Reverse Shoulder Arthroplasty

Felipe Lacerda, Alexandre Lädermann, Mahmoud Faisal Adam, Angélique Delarue, Céline Daniel, Philippe Collin

The Hive - Musculoskeletal Journal · 17.01.2025 · 1 (1)

DOI: 10.70885/hmsj.2025.01.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Hive - Musculoskeletal Journal, online erschienen am 17.01.2025. Verfasst von Felipe Lacerda und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

A major challenge of the reverse shoulder arthroplasty (RSA) is to restore postoperative range of motion, especially internal and external rotation. Attempting to address this issue, several modifications to the prosthesis design have been made.

Purpose

This study aimed to compare functional internal rotation (fIR) outcomes following RSA with different humeral implant designs.

Methods

We conducted a retrospective comparative analysis of data from 384 patients, each with a minimum of two years of follow-up, who underwent RSA with two distinct implant models: an inlay 155° neck-shaft angle and an onlay 145° neck-shaft angle. We assessed the postoperative progress of fIR based on type I IR (with the hand blocked against the buttock), type II IR (involving lumbar sliding), and type III IR (characterized by smooth motion). We categorized type I as non-fIR, while types II and III were considered as fIR. To analyze the influence of subscapularis repair on fRI, both groups were further categorized into two subgroups: those with repaired subscapularis (subgroup R) and those without repaired subscapularis (subgroup NR).

Results

No statistically significant difference was observed when comparing postoperative fIR between the two groups. Within the entire cohort, patients in subgroup R exhibited superior fIR outcomes compared to subgroup NR (40% type III vs. 19% type III, respectively; p

Zitieren

APA

Lacerda, F., Lädermann, A., Adam, M. F., Delarue, A., Daniel, C., & Collin, P. (2025). Subscapularis Tendon Repair Improves Functional Internal Rotation after Onlay Design Reverse Shoulder Arthroplasty. The Hive - Musculoskeletal Journal, 1(1). https://doi.org/10.70885/hmsj.2025.01.002

Vancouver

Lacerda F, Lädermann A, Adam MF, Delarue A, Daniel C, Collin P. Subscapularis Tendon Repair Improves Functional Internal Rotation after Onlay Design Reverse Shoulder Arthroplasty. The Hive - Musculoskeletal Journal. 2025;1(1). doi:10.70885/hmsj.2025.01.002

BibTeX
@article{Lacerda2025,
  author = {Lacerda, Felipe and Lädermann, Alexandre and Adam, Mahmoud Faisal and Delarue, Angélique and Daniel, Céline and Collin, Philippe},
  title = {Subscapularis Tendon Repair Improves Functional Internal Rotation after Onlay Design Reverse Shoulder Arthroplasty},
  journal = {The Hive - Musculoskeletal Journal},
  year = {2025},
  volume = {1},
  number = {1},
  doi = {10.70885/hmsj.2025.01.002}
}
Kostenlos starten →