EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Prospective Evaluation of Outcomes After Volar Locking Plate Fixation in Distal Radius Fractures

Muhammad Atiqur Rahman, Dewan Afsana Shomee, Taufiq Morshed

TAJ: Journal of Teachers Association · 01.06.2026 · 39 (2) · 309-313

DOI: 10.70818/taj.v39i2.0721 ↗

Kurz gefasst

Fachartikel in der Zeitschrift TAJ: Journal of Teachers Association, online erschienen am 01.06.2026. Verfasst von Muhammad Atiqur Rahman und 2 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Distal radius fractures are among the most common upper limb injuries and may lead to significant functional impairment if not properly managed. Volar locking plate fixation has emerged as an effective technique for achieving stable fixation and early mobilization.

Methods

This prospective observational study was conducted at NITOR over a 24-month period, including 40 patients with displaced distal radius fractures. All patients underwent open reduction and internal fixation using a volar locking plate. Functional outcomes were assessed using the Modified Green and O’Brien score, Gartland and Werley score, and QuickDASH score. Radiological parameters including radial height, radial inclination, volar tilt, ulnar variance, and articular incongruity were evaluated. Follow-up assessments were performed at 1, 3, and 6 months postoperatively.

Results

The mean age of patients was 48.6 ± 15.2 years, with falls being the most common mechanism of injury (65%). Functional scores showed significant improvement over time. The Modified Green and O’Brien score improved from 77.25 ± 10.54 at 1 month to 86.38 ± 10.61 at 6 months. Similarly, QuickDASH scores decreased from 23.01 ± 10.39 to 13.64 ± 10.76, indicating reduced disability. At final follow-up, 47.5% of patients achieved excellent outcomes. Radiographic evaluation demonstrated satisfactory anatomical restoration. Complications were minimal, including superficial infection (5%) and transient neuropathy (2.5%), with no implant failure or tendon rupture.

Conclusion

Volar locking plate fixation is a safe and effective method for managing distal radius fractures, providing stable anatomical restoration, enabling early mobilization, and resulting in favorable functional and radiological outcomes with minimal complications.

Zitieren

APA

Rahman, M. A., Shomee, D. A., & Morshed, T. (2026). Prospective Evaluation of Outcomes After Volar Locking Plate Fixation in Distal Radius Fractures. TAJ: Journal of Teachers Association, 39(2), 309-313. https://doi.org/10.70818/taj.v39i2.0721

Vancouver

Rahman MA, Shomee DA, Morshed T. Prospective Evaluation of Outcomes After Volar Locking Plate Fixation in Distal Radius Fractures. TAJ: Journal of Teachers Association. 2026;39(2):309-313. doi:10.70818/taj.v39i2.0721

BibTeX
@article{Rahman2026,
  author = {Rahman, Muhammad Atiqur and Shomee, Dewan Afsana and Morshed, Taufiq},
  title = {Prospective Evaluation of Outcomes After Volar Locking Plate Fixation in Distal Radius Fractures},
  journal = {TAJ: Journal of Teachers Association},
  year = {2026},
  volume = {39},
  number = {2},
  pages = {309--313},
  doi = {10.70818/taj.v39i2.0721}
}
Kostenlos starten →