Central Venous-To-Arterial Pco2 Difference and Central Venous Oxygen Saturation in Prediction of Extubation Failure in Critically Ill Patients
Pacific Journal of Medical Research · 30.06.2026 · 3 (2) · 69-77
DOI: 10.70818/pjmr.v03i02.0217 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pacific Journal of Medical Research, online erschienen am 30.06.2026. Verfasst von Fahmida Khatun Padma und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Beatmung und Weaning
Abstract (Originalsprache)
Background
In critically ill patients, tissue hypoxia is a leading mechanism of multiple organ failure and death. Therefore, the prediction of extubation failure is a crucial task. Extubation failure occurs in approximately 10–30% of all patients meeting the readiness criteria and have tolerated a spontaneous breathing trial. Extubation failure is associated with prolonged mechanical ventilation, as well as increase morbidity and mortality.
Objectives
The purpose of this study was to evaluate the role of central venous-to-arterial carbon dioxide pressure difference and central venous oxygen saturation for prediction of extubation failure in critically ill patients.
Methods
This prospective observational study was carried out in the Department of Anesthesiology and Intensive Care Unit, Chittagong Medical College Hospital, Chattogram, Bangladesh. A total of 67 critically ill patients were enrolled by convenient sampling. Guardian of the patients (who was selected for spontaneous breathing trial (SBT)/extubation according to ICU protocol and decision was taken by ICU consultant) was informed regarding the study and written consent was obtained. Central Venous-to-Arterial PCO2 Difference (∆PCO2) was measured immediately before SBT and 60 min after SBT initiation which express as ∆ - ∆ PCO2 and central venous oxygen saturation (ScvO2) were measured immediately before SBT and 60 min after SBT initiation which was expressed as ∆ScvO2. patients who maintained spontaneous respiration for 48 hours after extubation terms as successful extubation and who needed reintubation within 48 hours termed as extubation failure.
Results
In this present study, out of 67 cases, extubation failure was observed among 13 (19.4%) patients. According to p value, there was no statistically significant differences were found between extubation success and failure group regarding the parameters at ventilatory settings, ABG and VBG findings just before and 60 minutes after SBT. Mean (±SD) ∆ - ∆ PCO2 (%) were 27.93 ± 82.02 and 23.55 ± 63.19 in extubation success and extubation failure group respectively (p=0.858). The mean (±SD) ∆ ScvO2 (%) was 1.26 ± 11.71 in extubation success group and -0.27 ± 17.65 in extubation failure group (p=0.710). Logistic regression analysis for association of age, gender, ∆ - ∆ PCO2 (%) and ∆ ScvO2 (%) to extubation failure showed that, no statistically significant association was found (p>0.05). ROC analysis, the AUC for extubation failure (EF) was 0.503 for ∆ - ∆ PCO2 (95% confidence interval: 0.322–0.683) (p=0.975) and 0.466 for ∆ ScvO2 (95% confidence interval: 0.270–0.661) (p=0.704). Its indicates that there was no significant role of ∆ - ∆ PCO2 or ∆ ScvO2 values for prediction of extubation failure.
Conclusion
Prediction of successful extubation by implementing accurate and easy-to-obtain bedside measurements is tempting and risky at the same time. In this prospective observational study, we tested role of central venous-to-arterial carbon dioxide pressure difference and central venous oxygen saturation for prediction of extubation failure. Both ∆ - ∆PCO2 and ∆ ScvO2 were decreased in extubation failure group without statistically significant differences. Further large sample investigations may determine whether these parameters could assist a robust prediction of the extubation outcome of critically ill ICU patients.
Zitieren
APA
Padma, F. K., Nath, R. K., Bhuiyan, A. F. M. T., Absar, S., & Shanta, S. N. (2026). Central Venous-To-Arterial Pco2 Difference and Central Venous Oxygen Saturation in Prediction of Extubation Failure in Critically Ill Patients. Pacific Journal of Medical Research, 3(2), 69-77. https://doi.org/10.70818/pjmr.v03i02.0217
Vancouver
Padma FK, Nath RK, Bhuiyan AFMT, Absar S, Shanta SN. Central Venous-To-Arterial Pco2 Difference and Central Venous Oxygen Saturation in Prediction of Extubation Failure in Critically Ill Patients. Pacific Journal of Medical Research. 2026;3(2):69-77. doi:10.70818/pjmr.v03i02.0217
BibTeX
@article{Padma2026,
author = {Padma, Fahmida Khatun and Nath, Ranjan Kumar and Bhuiyan, Abul Fateh Mohammad Tareq and Absar, Sanjida and Shanta, Shamsun Nahar},
title = {Central Venous-To-Arterial Pco2 Difference and Central Venous Oxygen Saturation in Prediction of Extubation Failure in Critically Ill Patients},
journal = {Pacific Journal of Medical Research},
year = {2026},
volume = {3},
number = {2},
pages = {69--77},
doi = {10.70818/pjmr.v03i02.0217}
}