Usefulness of Clinical and Laboratory Parameters for Differentiation of Biliary Atresia from Idiopathic Neonatal Hepatitis: Experience in a Tertiary Care Hospital of Bangladesh
Barind Medical College Journal · 30.06.2026 · 12 (1) · 313-319
DOI: 10.70818/bmcj.v012i01.377 ↗Kurz gefasst
Fachartikel in der Zeitschrift Barind Medical College Journal, online erschienen am 30.06.2026. Verfasst von Emdadul Haque und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Biliary atresia (BA) is a progressive fibro-inflammatory disorder and an important cause of neonatal cholestasis. Early differentiation of BA from idiopathic neonatal hepatitis (INH) is essential for timely surgical intervention and improved outcomes. Serum gamma-glutamyl transferase (GGT) may serve as a useful biochemical marker for this differentiation.
Objective
To evaluate the diagnostic accuracy of various clinical and laboratory parameters in differentiating biliary atresia (BA) from idiopathic neonatal hepatitis (INH). Methodology: This cross-sectional study was conducted in the Department of Pediatric Gastroenterology, Hepatology and Nutrition, Bangladesh Shishu Hospital and Institute, Dhaka, Bangladesh from January to December 2025. A total of 42 infants with neonatal cholestasis were included, comprising 22 BA and 20 INH cases. Clinical characteristics, liver function parameters, and serum GGT levels were evaluated. Receiver operating characteristic (ROC) curve analysis was performed to determine the optimal GGT cut-off value, sensitivity, specificity, and area under the curve (AUC).
Results
The mean birth weight was significantly higher in BA than in INH (2.9 ± 0.26 vs. 2.6 ± 0.5 kg; p = 0.008). Persistent pale stools were more frequent in BA (86.4% vs. 25.0%; p < 0.001). Serum GGT was significantly higher in BA than in INH (709.09 ± 221.03 vs. 353.0 ± 146.80 IU/L; p < 0.001). ROC analysis demonstrated an AUC of 0.910 (95% CI: 0.827–1.000). At a cut-off value of 390 IU/L, sensitivity and specificity were 86.4% and 70.0%, respectively.
Conclusion
Serum GGT demonstrated high diagnostic accuracy and may be a useful biochemical marker for differentiating BA from INH. However, it should be interpreted alongside clinical findings and other diagnostic investigations.
Zitieren
APA
Haque, E., Kamal, M., & Aziz, T. (2026). Usefulness of Clinical and Laboratory Parameters for Differentiation of Biliary Atresia from Idiopathic Neonatal Hepatitis: Experience in a Tertiary Care Hospital of Bangladesh. Barind Medical College Journal, 12(1), 313-319. https://doi.org/10.70818/bmcj.v012i01.377
Vancouver
Haque E, Kamal M, Aziz T. Usefulness of Clinical and Laboratory Parameters for Differentiation of Biliary Atresia from Idiopathic Neonatal Hepatitis: Experience in a Tertiary Care Hospital of Bangladesh. Barind Medical College Journal. 2026;12(1):313-319. doi:10.70818/bmcj.v012i01.377
BibTeX
@article{Haque2026,
author = {Haque, Emdadul and Kamal, MA and Aziz, Tanzilul},
title = {Usefulness of Clinical and Laboratory Parameters for Differentiation of Biliary Atresia from Idiopathic Neonatal Hepatitis: Experience in a Tertiary Care Hospital of Bangladesh},
journal = {Barind Medical College Journal},
year = {2026},
volume = {12},
number = {1},
pages = {313--319},
doi = {10.70818/bmcj.v012i01.377}
}
EUVIMED