Background
Undescended testis is a common urogenital anomaly in childhood that can result in infertility, atrophy of the affected testicle, torsion and malignancy, if not diagnosed and treated at an early age. Grey scale ultrasonography is readily available, inexpensive, non-invasive, and without ionizing radiation. But, it still has to be validated with advanced imaging modalities like diffusion-weighted magnetic resonance imaging.
Objective
To determine the diagnostic accuracy of grey scale ultrasonography in detecting undescended testes, taking diffusion-weighted magnetic resonance imaging as the gold standard.
Methods
The cross sectional validation study was carried out in the Department of Radiology of Mardan Medical College, Mardan from 30 October 2024 to 30 April 2025. The number of cases included was 138 male patients aged from 1-15 years who were clinically suspected to have undescended testes, using non-probability consecutive sampling. Those who had undergone inguinal surgery, major congenital anomalies or who were contra-indicated for MRI, or who had renal failure, were excluded. All patients were initially scanned by grey scale ultrasonography and then by diffusion-weighted MRI. DW-MRI findings were correlated with ultrasound findings. All of the sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy, likelihood ratios, and ROC analysis were obtained on SPSS version 25.0. A p-value ≤0.05 was considered statistically significant.
Results
The mean age of patients was 6.1 ± 3.5 years. DW-MRI confirmed undescended testes in 42 (30.4%) patients, while grey scale ultrasonography detected undescended testes in 43 (31.2%) patients. Grey scale ultrasonography showed 38 true positive, 91 true negative, 5 false positive, and 4 false negative results. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 90.5%, 94.8%, 88.4%, 95.8%, and 93.5%, respectively. The association between grey scale ultrasonography and DW-MRI findings was statistically significant (p
Zitieren
APA
Ahmad, M., Yousaf, H., Hajra, Mahmood, A., Yousaf, M., & Janan, Z. (2025). Diagnostic Accuracy of Grey Scale Ultrasonography in Detecting Undescended Testes Taking Diffusion Weighted Magnetic Resonance Imaging as Gold Standard. Indus Journal of Bioscience Research, 3(6), 1547-1552. https://doi.org/10.70749/ijbr.v3i6.3295
Vancouver
Ahmad M, Yousaf H, Hajra, Mahmood A, Yousaf M, Janan Z. Diagnostic Accuracy of Grey Scale Ultrasonography in Detecting Undescended Testes Taking Diffusion Weighted Magnetic Resonance Imaging as Gold Standard. Indus Journal of Bioscience Research. 2025;3(6):1547-1552. doi:10.70749/ijbr.v3i6.3295
BibTeX
@article{Ahmad2025,
author = {Ahmad, Maria and Yousaf, Haroon and Hajra and Mahmood, Azra and Yousaf, Mehreen and Janan, Zubair},
title = {Diagnostic Accuracy of Grey Scale Ultrasonography in Detecting Undescended Testes Taking Diffusion Weighted Magnetic Resonance Imaging as Gold Standard},
journal = {Indus Journal of Bioscience Research},
year = {2025},
volume = {3},
number = {6},
pages = {1547--1552},
doi = {10.70749/ijbr.v3i6.3295}
}
EUVIMED