Comparison of K-reading Measurements through Autorefraction and Biometry Machine

Khalida Aziz, Saad Rauf Khan, M Azam Khan, Ayisha Shakeel, Shaista Haider, Munazzah Yaqub

Indus Journal of Bioscience Research · 30.05.2025 · 3 (5) · 1391-1394

DOI: 10.70749/ijbr.v3i5.1919 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indus Journal of Bioscience Research, online erschienen am 30.05.2025. Verfasst von Khalida Aziz und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare steep, flat, and average corneal keratometry (K) readings obtained using an autorefractor and an optical biometer. Study Design: Prospective cross-sectional study. Place and Duration of Study: Department of Ophthalmology, PAF Hospital, Islamabad, Pakistan, January to July 2024. Methodology: Thirty-eight participants (76 eyes) underwent keratometric assessment using a Topcon KR-800 Auto-Kerato-Refractometer and a NIDEK AL-Scan optical biometer. Three consecutive readings were obtained with each instrument and averaged. Device measurements were compared using paired-samples t-tests, Bland–Altman analysis, and intraclass correlation coefficients (ICC).

Results

The autorefractor and biometer recorded mean steep K values of 44.15 ± 1.59 D and 44.10 ± 1.55 D, flat K values of 43.21 ± 1.53 D and 43.15 ± 1.49 D, and average K values of 43.65 ± 1.46 D and 43.61 ± 1.47 D, respectively. The corresponding paired mean differences (autorefractor minus biometer) were 0.047 D (95% CI: −0.040 to 0.134; p = 0.283), 0.062 D (95% CI: −0.016 to 0.140; p = 0.118), and 0.041 D (95% CI: −0.048 to 0.131; p = 0.361). Bland–Altman limits of agreement ranged from −0.70 to +0.79 D, −0.61 to +0.73 D, and −0.73 to +0.81 D, respectively. Single-measure ICCs were 0.971, 0.968, and 0.972 (all p < 0.001).

Conclusion

The two devices yielded closely matched mean keratometric readings and high relative agreement. However, individual between-device differences within the observed limits of agreement should be considered before treating their measurements as interchangeable for clinical decisions.

Zitieren

APA

Aziz, K., Khan, S. R., Khan, M. A., Shakeel, A., Haider, S., & Yaqub, M. (2025). Comparison of K-reading Measurements through Autorefraction and Biometry Machine. Indus Journal of Bioscience Research, 3(5), 1391-1394. https://doi.org/10.70749/ijbr.v3i5.1919

Vancouver

Aziz K, Khan SR, Khan MA, Shakeel A, Haider S, Yaqub M. Comparison of K-reading Measurements through Autorefraction and Biometry Machine. Indus Journal of Bioscience Research. 2025;3(5):1391-1394. doi:10.70749/ijbr.v3i5.1919

BibTeX
@article{Aziz2025,
  author = {Aziz, Khalida and Khan, Saad Rauf and Khan, M Azam and Shakeel, Ayisha and Haider, Shaista and Yaqub, Munazzah},
  title = {Comparison of K-reading Measurements through Autorefraction and Biometry Machine},
  journal = {Indus Journal of Bioscience Research},
  year = {2025},
  volume = {3},
  number = {5},
  pages = {1391--1394},
  doi = {10.70749/ijbr.v3i5.1919}
}
Kostenlos starten →