EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluating Diagnostic Accuracy of Ultrasound for Malignant Thyroid Nodules in Women Compared to Fine Needle Aspiration Cytology

Liaqat Ali, Munazza Zafar, Sohail Ahmed, Afsana Hadi, Shabana Lakhair, Sadam Hussain

Indus Journal of Bioscience Research · 30.04.2025 · 3 (4) · 1412-1416

DOI: 10.70749/ijbr.v3i4.3341 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indus Journal of Bioscience Research, online erschienen am 30.04.2025. Verfasst von Liaqat Ali und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Thyroid nodules are common in women and most are benign, but some may be malignant and require early diagnosis. Ultrasound is the first imaging methods used for evaluation while fine needle aspiration cytology are considered the reference standard for confirming malignancy.

Objective

To evaluate the diagnostic accuracy of ultrasound for detecting malignant thyroid nodules in women compared with fine needle aspiration cytology. Study Design: Cross-sectional validation study. Duration and Place of Study: This study was conducted from 25 June 2024 to 24 January 2025 in the Department of Radiology, Pir Abdul Qadir Shah Jeelani Institute of Medical Sciences, Gambat. Methodology: A total of 100 women aged 16 years and above with clinically palpable solitary thyroid nodules were included by consecutive sampling. All patients underwent high-resolution ultrasound followed by ultrasound-guided fine needle aspiration cytology. Quantitative variables were presented as mean ± standard deviation, while categorical variables were presented as frequency and percentage. Diagnostic accuracy measures including sensitivity, specificity, positive predictive value, negative predictive value and overall diagnostic accuracy were calculated using IBM Statistical Package for the Social Sciences version 26.

Results

The mean age was 41.16 ± 11.61 years. On ultrasound, 39 (39.0%) nodules were reported as malignant, while fine needle aspiration cytology identified 20 (20.0%) malignant nodules. There were 19 true positive, 60 true negative, 20 false positive and 1 false negative cases. Ultrasound showed sensitivity of 95.0%, specificity of 75.0%, positive predictive value of 48.72%, negative predictive value of 98.36%, and overall diagnostic accuracy of 79.0%.

Conclusion

Ultrasound showed high sensitivity and excellent negative predictive value for detecting malignant thyroid nodules in women

Zitieren

APA

Ali, L., Zafar, M., Ahmed, S., Hadi, A., Lakhair, S., & Hussain, S. (2025). Evaluating Diagnostic Accuracy of Ultrasound for Malignant Thyroid Nodules in Women Compared to Fine Needle Aspiration Cytology. Indus Journal of Bioscience Research, 3(4), 1412-1416. https://doi.org/10.70749/ijbr.v3i4.3341

Vancouver

Ali L, Zafar M, Ahmed S, Hadi A, Lakhair S, Hussain S. Evaluating Diagnostic Accuracy of Ultrasound for Malignant Thyroid Nodules in Women Compared to Fine Needle Aspiration Cytology. Indus Journal of Bioscience Research. 2025;3(4):1412-1416. doi:10.70749/ijbr.v3i4.3341

BibTeX
@article{Ali2025,
  author = {Ali, Liaqat and Zafar, Munazza and Ahmed, Sohail and Hadi, Afsana and Lakhair, Shabana and Hussain, Sadam},
  title = {Evaluating Diagnostic Accuracy of Ultrasound for Malignant Thyroid Nodules in Women Compared to Fine Needle Aspiration Cytology},
  journal = {Indus Journal of Bioscience Research},
  year = {2025},
  volume = {3},
  number = {4},
  pages = {1412--1416},
  doi = {10.70749/ijbr.v3i4.3341}
}