EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Diagnostic Accuracy of Chest Ultrasonography and Chest X-Ray for Diagnosis of Pneumothorax Taking Computed Tomography as Gold Standard

Shameen Ashfaq, Asim Shoukat, Muhammad Saeed Ashraf

Indus Journal of Bioscience Research · 30.04.2025 · 3 (4) · 1394-1400

DOI: 10.70749/ijbr.v3i4.3297 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indus Journal of Bioscience Research, online erschienen am 30.04.2025. Verfasst von Shameen Ashfaq und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pneumothorax is an emergency diagnosis as lateness may lead to respiratory failure, tension physiology and preventable morbidity. A chest radiography is often accessible, though it is potentially inaccurate with small or in supine pneumothoraces; a fast bedside alternative is provided by chest ultrasonography.

Purpose

The purpose of the study is to investigate the accuracy of chest ultrasonography and chest X-ray in the diagnosis of pneumothorax with the gold standard of computed tomography.

Methods

The model paper was written as a cross- sectional validation study, which was undertaken in the Department of Radiology, Allied Hospital, Faisalabad from 15-6-2024 to 15 December 2024. A magnitude of 230 clinically suspected patients between the age group of 18-60 years were evaluated. All had CT chest, chest ultrasonography and chest X-ray. Confidence intervals were calculated as sensitivity, specificity, positive predictive value, negative predictive value and accuracy.

Findings

CT established the presence of pneumothorax in 84/230 patients (36.5%). A total of 76 true positive, 140 true negative were identified by some chest ultrasonography that is sensitive at 90.5, specificity as 95.9, PPV as 92.7, NPV at 94.6% and accuracy at 93.9%. Chest X-ray identified a total of 58 true positive and 142 true negative cases with sensitivity of 69.0, specificity of 97.3, PPV of 93.5, NPV of 84.5 and Accuracy of 87.0. Ultrasonography showed a high sensitivity compared to the chest X-ray (p

Zitieren

APA

Ashfaq, S., Shoukat, A., & Ashraf, M. S. (2025). Diagnostic Accuracy of Chest Ultrasonography and Chest X-Ray for Diagnosis of Pneumothorax Taking Computed Tomography as Gold Standard. Indus Journal of Bioscience Research, 3(4), 1394-1400. https://doi.org/10.70749/ijbr.v3i4.3297

Vancouver

Ashfaq S, Shoukat A, Ashraf MS. Diagnostic Accuracy of Chest Ultrasonography and Chest X-Ray for Diagnosis of Pneumothorax Taking Computed Tomography as Gold Standard. Indus Journal of Bioscience Research. 2025;3(4):1394-1400. doi:10.70749/ijbr.v3i4.3297

BibTeX
@article{Ashfaq2025,
  author = {Ashfaq, Shameen and Shoukat, Asim and Ashraf, Muhammad Saeed},
  title = {Diagnostic Accuracy of Chest Ultrasonography and Chest X-Ray for Diagnosis of Pneumothorax Taking Computed Tomography as Gold Standard},
  journal = {Indus Journal of Bioscience Research},
  year = {2025},
  volume = {3},
  number = {4},
  pages = {1394--1400},
  doi = {10.70749/ijbr.v3i4.3297}
}
Kostenlos starten →