EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Seismic Performance Evaluation of Laboratory Building with Concrete Column Jacketing Based on ASCE 41-17 using Pushover Analysis

Aditya Rihadatul Aisy, Josia Irwan Rastandi, Jessica Sjah

G-Tech: Jurnal Teknologi Terapan · 02.07.2026 · 10 (3) · 982-992

DOI: 10.70609/g-tech.v10i3.9704 ↗

Kurz gefasst

Fachartikel in der Zeitschrift G-Tech: Jurnal Teknologi Terapan, online erschienen am 02.07.2026. Verfasst von Aditya Rihadatul Aisy und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents comprehensive seismic performance evaluation on the laboratory building structure designed using the old regulations (SNI 1726:2002 and SNI 2847:2002) and has been strengthened with concrete column jacketing through a pushover analysis procedure based on ASCE 41-17 guidelines. Based on the global performance of the structure, the structure drift have met the performance targets with a maximum drift of 1.92% for the X direction and 1.96% for the Y direction. Based on the analysis of the deformation-controlled action, the rotation values ​​that occur in the beam components have met the performance targets with a maximum rotation of 0.0066 for negative moments and 0.0073 for positive moments. While the strain that occurs in the column components have also met the performance targets with a maximum strain of 0.0032 for rebar compression strain, 0.0131 for rebar tensile strain, and 0.0024 for concrete compression strain. Then, based on the analysis of the force-controlled action, the DCR values ​​for shear and axial in the column components have met the performance targets with a maximum value for shear of 0.89 and for axial of 0.61. While the DCR values ​​for shear in the beam components partially exceed the performance targets with a maximum value of 1.29.

Zitieren

APA

Aisy, A. R., Rastandi, J. I., & Sjah, J. (2026). Seismic Performance Evaluation of Laboratory Building with Concrete Column Jacketing Based on ASCE 41-17 using Pushover Analysis. G-Tech: Jurnal Teknologi Terapan, 10(3), 982-992. https://doi.org/10.70609/g-tech.v10i3.9704

Vancouver

Aisy AR, Rastandi JI, Sjah J. Seismic Performance Evaluation of Laboratory Building with Concrete Column Jacketing Based on ASCE 41-17 using Pushover Analysis. G-Tech: Jurnal Teknologi Terapan. 2026;10(3):982-992. doi:10.70609/g-tech.v10i3.9704

BibTeX
@article{Aisy2026,
  author = {Aisy, Aditya Rihadatul and Rastandi, Josia Irwan and Sjah, Jessica},
  title = {Seismic Performance Evaluation of Laboratory Building with Concrete Column Jacketing Based on ASCE 41-17 using Pushover Analysis},
  journal = {G-Tech: Jurnal Teknologi Terapan},
  year = {2026},
  volume = {10},
  number = {3},
  pages = {982--992},
  doi = {10.70609/g-tech.v10i3.9704}
}