EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reinforcing Column Enlargement Using the Chemical Anchor Method in a Hotel Construction Project

Ety Fitriyani, Hulfa Istikomah, Vivid Lucha Deanggi, Saddam Mirza, Demmy Adhi Mulya Darma, Mutia Gina Savira

G-Tech: Jurnal Teknologi Terapan · 10.07.2026 · 10 (3) · 1192-1201

DOI: 10.70609/g-tech.v10i3.10257 ↗

Kurz gefasst

Fachartikel in der Zeitschrift G-Tech: Jurnal Teknologi Terapan, online erschienen am 10.07.2026. Verfasst von Ety Fitriyani und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to identify the need for reinforcing column enlargement of a coffee shop structure in a hotel project due to concerns related to the adequacy of the existing column capacity during the construction stage. The evaluation was conducted through a three-dimensional structural reanalysis using SAP2000, based on the design drawings, material quality, and load combinations as specified in the project standards. The results of the analysis showed that most of the existing K1 columns, measuring 150 x 1000 mm, had a stress ratio exceeding 1.0, with the highest value reaching 1.32. It means that they do not meet the strength criteria and need reinforcement. The selected alternative was to enlarge the column dimensions to 250 x 1000 mm by adding 14D19 reinforcement and applying the chemical anchor method to ensure monolithic action between the old and new concrete. The reanalysis reduced the maximum stress ratio of the reinforced columns to 0.85, so that all columns satisfied the strength criteria. Verification of the chemical anchor system showed that all failure modes had load-to-capacity ratios below 1.0, with a maximum of 0.56 in the pull-out/bond mode. In terms of quality, time, and cost, the chemical anchor method was more efficient than the steel jacketing composite method, with an estimated 30–40% reduction in execution time and approximately 25% lower cost.

Zitieren

APA

Fitriyani, E., Istikomah, H., Deanggi, V. L., Mirza, S., Darma, D. A. M., & Savira, M. G. (2026). Reinforcing Column Enlargement Using the Chemical Anchor Method in a Hotel Construction Project. G-Tech: Jurnal Teknologi Terapan, 10(3), 1192-1201. https://doi.org/10.70609/g-tech.v10i3.10257

Vancouver

Fitriyani E, Istikomah H, Deanggi VL, Mirza S, Darma DAM, Savira MG. Reinforcing Column Enlargement Using the Chemical Anchor Method in a Hotel Construction Project. G-Tech: Jurnal Teknologi Terapan. 2026;10(3):1192-1201. doi:10.70609/g-tech.v10i3.10257

BibTeX
@article{Fitriyani2026,
  author = {Fitriyani, Ety and Istikomah, Hulfa and Deanggi, Vivid Lucha and Mirza, Saddam and Darma, Demmy Adhi Mulya and Savira, Mutia Gina},
  title = {Reinforcing Column Enlargement Using the Chemical Anchor Method in a Hotel Construction Project},
  journal = {G-Tech: Jurnal Teknologi Terapan},
  year = {2026},
  volume = {10},
  number = {3},
  pages = {1192--1201},
  doi = {10.70609/g-tech.v10i3.10257}
}