Ultrasonografía de la vaina del nervio óptico: utilidad en la evaluación no invasiva de la hipertensión endocraneana
Salud Medicina e Innovación Journal · 24.06.2026 · 4 (2) · 191-213
DOI: 10.70577/qcnp9315 ↗Kurz gefasst
Fachartikel in der Zeitschrift Salud Medicina e Innovación Journal, online erschienen am 24.06.2026. Verfasst von Jimmy Fernando Yaguana Torres und 4 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Introduction
The recognition of intracranial hypertension represents an important framework for the management of a critical neurological condition, often associated with clinical deterioration and the risk of secondary brain injury. Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) is a non-invasive, rapid, and reproducible tool for estimating changes related to intracranial pressure, with particular importance in contexts where invasive monitoring or neuroimaging may not be immediately available.
Objective
To evaluate the usefulness of ultrasonographic ONSD measurement as an alternative method for detecting, monitoring, and clinically assessing intracranial hypertension. Methodology: A structured narrative review of scientific articles on ONSD and intracranial hypertension was conducted, including observational studies, cohort studies, reviews, case reports, and studies in adult, pediatric, neurocritical, and healthy populations. Methodological characteristics, study population, measurement technique, cutoff points, correlation with intracranial pressure, neuroimaging, clinical evolution, and reported limitations were analyzed.
Results
The reviewed evidence shows that ONSD is most useful when compared with invasive intracranial pressure monitoring, neuroimaging findings, or dynamic changes following therapeutic interventions. Its performance was relevant in neurocritical patients, traumatic brain injury, pediatric hydrocephalus, and stroke. In metabolic or systemic scenarios, such as hyponatremia and hepatic encephalopathy, it reflected possible changes related to cerebral edema, although with less consistent prognostic value.
Conclusions
ONSD constitutes a useful complementary tool within non-invasive neuromonitoring; however, it requires technical standardization, operator training, and population-specific cutoff points.
Zitieren
APA
Torres, J. F. Y., Arteaga, J. F. A., Fajardo, E. V. L., Abril, J. N. G., & Martínez, L. E. U. (2026). Ultrasonografía de la vaina del nervio óptico: utilidad en la evaluación no invasiva de la hipertensión endocraneana. Salud Medicina e Innovación Journal, 4(2), 191-213. https://doi.org/10.70577/qcnp9315
Vancouver
Torres JFY, Arteaga JFA, Fajardo EVL, Abril JNG, Martínez LEU. Ultrasonografía de la vaina del nervio óptico: utilidad en la evaluación no invasiva de la hipertensión endocraneana. Salud Medicina e Innovación Journal. 2026;4(2):191-213. doi:10.70577/qcnp9315
BibTeX
@article{Torres2026,
author = {Torres, Jimmy Fernando Yaguana and Arteaga, Jimmy Fabricio Achi and Fajardo, Emily Valeria López and Abril, Joselin Nicol Gutiérrez and Martínez, Luis Enrique Ushca},
title = {Ultrasonografía de la vaina del nervio óptico: utilidad en la evaluación no invasiva de la hipertensión endocraneana},
journal = {Salud Medicina e Innovación Journal},
year = {2026},
volume = {4},
number = {2},
pages = {191--213},
doi = {10.70577/qcnp9315}
}
EUVIMED