BARRIERS TO SELF-MONITORING OF BLOOD GLUCOSE LEVEL THROUGH GLUCOMETER IN DIABETIC PATIENTS VISITING A TERTIARY CARE HOSPITAL IN PESHAWAR, PAKISTAN: A CROSS-SECTIONAL STUDY
Khyber Journal of Medical Sciences · 30.06.2026 · 19 (2)
DOI: 10.70520/kjms.v19i2.914 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Khyber Journal of Medical Sciences, online erschienen am 30.06.2026. Verfasst von Faisal Hassan und 5 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
Objective
To determine the barriers to self-monitoring of blood glucose (SMBG) through glucometer among patients with diabetes mellitus (DM) visiting a tertiary care hospital in Peshawar, Pakistan.
Methods
This cross-sectional study was carried out in the Department of Medicine, Hayatabad Medical Complex, Peshawar, Pakistan, from 1st June 2025 to 20th December 2025. 267 patients aged 18-80 years with type 2 DM for at least one year and owning glucometer were enrolled through convenience sampling. Patients with medical emergencies and gestational DM were excluded. Demographic data (age, gender), clinical information (BMI, duration of DM, and HbA1c%), and 13 barriers to SMBG were analyzed using Statistical Package for Social Sciences, and presented as percentages and frequencies.
Results
Mean age was 54.0 ± 15.1 years, with median duration of DM of 7 years (IQR: 04 – 09). Most participants were male (n = 148, 55.4%), obese (n = 157, 58.9%), and had poor glycemic control (n = 173, 64.8%). The barriers most frequently reported were: ‘I forgot to check my blood glucose’(n = 166, 62.1%), ‘I have a fear of needles/pain’ (n = 162, 60.7%), ‘Tired of managing my diabetes mellitus’ (n = 158, 59.2%), ‘Checking blood glucose regularly is useless if I feel okay’ (n = 150, 56.2%), and ‘Doctor never asks or gives feedback on the sugar record’ (n = 149, 55.8%). Limited availability of strips, distrust of glucometer readings, and non-familiarity with glucometer use were among the other barriers.
Conclusions
Despite access to glucometers, many patients do not use them effectively. Forgetfulness, needle phobia, and diabetes burnout are the most common barriers to SMBG. Improving SMBG will require more than simply providing patients with glucometers.
Zitieren
APA
Hassan, F., Haq, A. U., Nadeem, H., Atta, A., Murtaza, Q., & Hashim, M. (2026). BARRIERS TO SELF-MONITORING OF BLOOD GLUCOSE LEVEL THROUGH GLUCOMETER IN DIABETIC PATIENTS VISITING A TERTIARY CARE HOSPITAL IN PESHAWAR, PAKISTAN: A CROSS-SECTIONAL STUDY. Khyber Journal of Medical Sciences, 19(2). https://doi.org/10.70520/kjms.v19i2.914
Vancouver
Hassan F, Haq AU, Nadeem H, Atta A, Murtaza Q, Hashim M. BARRIERS TO SELF-MONITORING OF BLOOD GLUCOSE LEVEL THROUGH GLUCOMETER IN DIABETIC PATIENTS VISITING A TERTIARY CARE HOSPITAL IN PESHAWAR, PAKISTAN: A CROSS-SECTIONAL STUDY. Khyber Journal of Medical Sciences. 2026;19(2). doi:10.70520/kjms.v19i2.914
BibTeX
@article{Hassan2026,
author = {Hassan, Faisal and Haq, Anwar Ul and Nadeem, Hira and Atta, Aiman and Murtaza, Qandeel and Hashim, Muhammad},
title = {BARRIERS TO SELF-MONITORING OF BLOOD GLUCOSE LEVEL THROUGH GLUCOMETER IN DIABETIC PATIENTS VISITING A TERTIARY CARE HOSPITAL IN PESHAWAR, PAKISTAN: A CROSS-SECTIONAL STUDY},
journal = {Khyber Journal of Medical Sciences},
year = {2026},
volume = {19},
number = {2},
doi = {10.70520/kjms.v19i2.914}
}
EUVIMED