AQUIFER PARAMETER VARIATION USING VERTICAL ELECTRICAL SOUNDING AND CONTOURING TECHNIQUES IN APETE-AKUFO PHASE II, AWOTAN-ASUNLE AREA OF IBADAN, SOUTH-WEST NIGERIA
Journal of African Advancement and Sustainability Studies · 21.11.2026
DOI: 10.70382/sjaass.v14i2.0104 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of African Advancement and Sustainability Studies, online erschienen am 21.11.2026. Verfasst von ISHOLA und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Subsurface characterization is essential for evaluating groundwater potential and assess the environmental impact of dumpsites. Vertical Electrical Sounding (VES) was carried out to study the subsurface condition of Apete-Akufo, Awotan-Asunle dumpsite area of Ibadan, aimed at determining the subsurface resistivity beneath the dumpsite, identifying the different geoelectric layers present, evaluating the depth and extent of leachate contamination. Ten (10) Vertical Electrical Sounding (VES) stations were occupied using Schlumberger electrode configuration with half-electrode spacing (AB/2) of 75m each and the field data were interpreted using Win Resist software to generate geoelectric models. The interpreted results revealed three to four geoelectric layers comprising the topsoil, weathered layer, fractured basement, and fresh basement. The top soil resistivity values range from 8.1Ωm to 800.2Ωm, the weathered layer resistivity (4.1-619.1Ωm), fractured basement resistivity ranges from 25.6Ωm to 105.6Ωm and fresh basement resistivity (25.7-1291.6Ωm) with curves types ranging from H-type to A-type and K-type across the different stations. Other aquifer properties were consequently determined; bedrock relief which ranges from 187.5 to 221.3m, Aquifer thickness (0.5 - 41.7m) and overburden thickness ranges from 2.7 to 44.5m among others. The aquifer protective capacity assessment, based on longitudinal conductance values, revealed that 10%, 20%, 60% and 10% were classified as poor, weak, moderate and good protective capacity status respectively. The location exhibiting low protective capacity will enhance the migration of contaminants into the groundwater system of the study area. Periodic groundwater quality monitoring is recommended particularly in locations with low aquifer protective capacity to minimize the impact of leachate contamination from the dumpsite.
Zitieren
APA
ISHOLA, & A., S. (2026). AQUIFER PARAMETER VARIATION USING VERTICAL ELECTRICAL SOUNDING AND CONTOURING TECHNIQUES IN APETE-AKUFO PHASE II, AWOTAN-ASUNLE AREA OF IBADAN, SOUTH-WEST NIGERIA. Journal of African Advancement and Sustainability Studies. https://doi.org/10.70382/sjaass.v14i2.0104
Vancouver
ISHOLA, A. S. AQUIFER PARAMETER VARIATION USING VERTICAL ELECTRICAL SOUNDING AND CONTOURING TECHNIQUES IN APETE-AKUFO PHASE II, AWOTAN-ASUNLE AREA OF IBADAN, SOUTH-WEST NIGERIA. Journal of African Advancement and Sustainability Studies. 2026. doi:10.70382/sjaass.v14i2.0104
BibTeX
@article{ISHOLA2026,
author = {ISHOLA and A., S.},
title = {AQUIFER PARAMETER VARIATION USING VERTICAL ELECTRICAL SOUNDING AND CONTOURING TECHNIQUES IN APETE-AKUFO PHASE II, AWOTAN-ASUNLE AREA OF IBADAN, SOUTH-WEST NIGERIA},
journal = {Journal of African Advancement and Sustainability Studies},
year = {2026},
doi = {10.70382/sjaass.v14i2.0104}
}
EUVIMED