Diagnostic Accuracy of Urine Reagent Strips for Rapid Bacterial Meningitis Diagnosis: A Cross-Sectional Validation Study in a Resource-Limited Setting
Journal of Pakistan Society of Internal Medicine · 20.11.2026 · 7 (4) · 321-325
DOI: 10.70302/jpsim.v7i4.2664 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Journal of Pakistan Society of Internal Medicine, online erschienen am 20.11.2026. Verfasst von Syed Ali Haziq Bukhari und 5 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To prospectively confirm the diagnostic performance of urine reagent strips in the detection of meningitis. Methodology: This cross-sectional study included patients aged 20–60 years with clinically suspected meningitis requiring lumbar puncture. The index test was a standardized urine reagent strip (Combur-10 Test®) applied to undiluted CSF, interpreted for leukocyte esterase, protein, and glucose according to manufacturer color gradings taking laboratory CSF analysis as gold standard test. Following parameters were statistically calculated for accuracy.
Results
Among 105 enrolled patients (mean age 38.5 ± 12.2 years; 55.2% male), the prevalence of meningitis by reference standard was 60.0% (63/105). Against this gold standard, the reagent strip method demonstrated a sensitivity of 86.5% (95% CI: 75.8–93.1), specificity of 88.4% (95% CI: 74.1–95.6), positive predictive value of 91.5% (95% CI: 82.0–96.2), and negative predictive value of 82.6% (95% CI: 69.7–90.8). The diagnostic accuracy is 87.6% (95% CI: 79.9 – 92.9). The area under the ROC curve was 0.91 (95% CI: 0.86 – 0.96) which shows excellent discriminatory ability.
Conclusion
Urine reagent strip are easily available, are cost effective and operationally feasible bedside diagnostic kits which can be used for a rapid diagnosis of meningitis in resource-limited settings.
Zitieren
APA
Bukhari, S. A. H., Shaukat, A., Ahmed, U., Irfan, M., Ahmad, Z., & Shaukat, M. (2026). Diagnostic Accuracy of Urine Reagent Strips for Rapid Bacterial Meningitis Diagnosis: A Cross-Sectional Validation Study in a Resource-Limited Setting. Journal of Pakistan Society of Internal Medicine, 7(4), 321-325. https://doi.org/10.70302/jpsim.v7i4.2664
Vancouver
Bukhari SAH, Shaukat A, Ahmed U, Irfan M, Ahmad Z, Shaukat M. Diagnostic Accuracy of Urine Reagent Strips for Rapid Bacterial Meningitis Diagnosis: A Cross-Sectional Validation Study in a Resource-Limited Setting. Journal of Pakistan Society of Internal Medicine. 2026;7(4):321-325. doi:10.70302/jpsim.v7i4.2664
BibTeX
@article{Bukhari2026,
author = {Bukhari, Syed Ali Haziq and Shaukat, Aamir and Ahmed, Umair and Irfan, Muhammad and Ahmad, Zaheer and Shaukat, Minahil},
title = {Diagnostic Accuracy of Urine Reagent Strips for Rapid Bacterial Meningitis Diagnosis: A Cross-Sectional Validation Study in a Resource-Limited Setting},
journal = {Journal of Pakistan Society of Internal Medicine},
year = {2026},
volume = {7},
number = {4},
pages = {321--325},
doi = {10.70302/jpsim.v7i4.2664}
}
EUVIMED