Detection of Residues by Use of Solid-Phase Extraction and Reversed Phase High-Performance Liquid Chromatography after Oral Administration of Amoxicillin in Bass Muscle
Taiwan Veterinary Journal · 01.06.2009 · 35 (2) · 66-74
DOI: 10.7009/tvj.200906.0066 ↗Kurz gefasst
Fachartikel in der Zeitschrift Taiwan Veterinary Journal, erschienen am 01.06.2009. Verfasst von Tzong‐Fu Kuo und 4 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref).
Abstract (Originalsprache)
An experimental trial was performed to establish an adequate depletion period of amoxicillin in bass. The amount of amoxicillin was applied by oral administration at the dose of 20 and 40 mg/kg body weight, and was given at a daily dose for five consecutive days. Amoxicillin levels were determined using a solid-phase extraction and high-performance liquid chromatography (HPLC) method. The drug was eluted from Mightysil RP-18 GP 250-4.6 mm φ5 m column with a mobile phase consisting of 0.005 M KH2PO4 buffer with pH 6.8-MeOH (90:10, v/v), at a flow rate of 1 mL/min. The effluent was monitored using a UV detector set at 210 nm. Each analysis required no longer than 15 mm. The validated concentration ranges of this method were 0.01 μg/mL to 10 μg/mL for working standard solutions, and 0.04 to 10 μg/g for muscle. Mean absolute recoveries were 78%. The limits of detection (LCD) and limits of quantitation (LOQ) for bass muscle were 0.04 and 0.1 quantitation g/g, respectively. After 5 consecutive oral doses of amoxicillin, residues in 6-h-postdosing (T(subscript max)) bass were at the maximum 0.84 and 1.18 μg/g (C(subscript max)) toward 20 and 40 mg/kg b.w. dosage, residue levels after a 72-h depletion decreased to below the methods limit of quantitation after last oral treatment. At the dosage (40 mg/kg b.w.), we suggested that the recommended withdraw period was 5 days.
Schlagwörter
Zitieren
APA
Kuo, T., Wang, Y., Sheu, S., Chang, M., & Wang, J. (2009). Detection of Residues by Use of Solid-Phase Extraction and Reversed Phase High-Performance Liquid Chromatography after Oral Administration of Amoxicillin in Bass Muscle. Taiwan Veterinary Journal, 35(2), 66-74. https://doi.org/10.7009/tvj.200906.0066
Vancouver
Kuo T, Wang Y, Sheu S, Chang M, Wang J. Detection of Residues by Use of Solid-Phase Extraction and Reversed Phase High-Performance Liquid Chromatography after Oral Administration of Amoxicillin in Bass Muscle. Taiwan Veterinary Journal. 2009;35(2):66-74. doi:10.7009/tvj.200906.0066
BibTeX
@article{Kuo2009,
author = {Kuo, Tzong‐Fu and Wang, Yueh-Kuei and Sheu, Shi‐Yuan and Chang, Ming-Huang and Wang, Jiann-Hsiung},
title = {Detection of Residues by Use of Solid-Phase Extraction and Reversed Phase High-Performance Liquid Chromatography after Oral Administration of Amoxicillin in Bass Muscle},
journal = {Taiwan Veterinary Journal},
year = {2009},
volume = {35},
number = {2},
pages = {66--74},
doi = {10.7009/tvj.200906.0066}
}
EUVIMED