The Effect of Using All Around Major Stabilizer on Dimensional Change of Zirconia Material Under Conventional Sintering
Al-Esraa University College Journal for Medical Sciences · 30.06.2026 · 7 (11) · 206-216
DOI: 10.70080/2790-7937.1091 ↗Kurz gefasst
Fachartikel in der Zeitschrift Al-Esraa University College Journal for Medical Sciences, online erschienen am 30.06.2026. Verfasst von Ali Thaer Kadhom und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Background: Zirconia had emerged as a highly promising material for the production of attractive dental restorations due to its mechanical properties. One of the biggest issues with zirconia long bridge affected on dimension after sintering. The dimensional change of a zirconia bridge of more than six units after sintering will be affected. The aim of study: To evaluate the dimensional changes that occur during the fabrication process of a monolithic stabilized zirconia full-anatomy bridge under the influence of all around major stabilizer. Materials and Methods: The cast and specimen were designed digitally by Exo-Cad software. The specimen was designed from a 14-units full-anatomy zirconia bridge with nine cones divided into two groups: G1: control group (without a major stabilizer) and the G2: experimental group (all around major stabilizer. The nine cones were used to measure the dimensional change after sintering. After milling the zirconia bridge cutting from the blank by diamond fissure bur, sinter the zirconia in the furnace under (conventional sintering). The time for sintering was 12 hours; after that, remove the zirconia bridge from the furnace and cut the major stabilizer with a diamond disc. The bridge was placed in the 3Shape desktop scan (3Shape E1 Dental Lab Scanner, Denmark) for scanning; thereafter, the (STL) file is imported into Exo-CAD software for merging with the first designed bridge to determine the dimensional difference between each groups. The data were statistically analyzed using One-way ANOVA, followed by (GH) test to compare the groups at a significance level of p
Zitieren
APA
Kadhom, A. T., & Hummudi, I. M. (2026). The Effect of Using All Around Major Stabilizer on Dimensional Change of Zirconia Material Under Conventional Sintering. Al-Esraa University College Journal for Medical Sciences, 7(11), 206-216. https://doi.org/10.70080/2790-7937.1091
Vancouver
Kadhom AT, Hummudi IM. The Effect of Using All Around Major Stabilizer on Dimensional Change of Zirconia Material Under Conventional Sintering. Al-Esraa University College Journal for Medical Sciences. 2026;7(11):206-216. doi:10.70080/2790-7937.1091
BibTeX
@article{Kadhom2026,
author = {Kadhom, Ali Thaer and Hummudi, Israa Mohammed},
title = {The Effect of Using All Around Major Stabilizer on Dimensional Change of Zirconia Material Under Conventional Sintering},
journal = {Al-Esraa University College Journal for Medical Sciences},
year = {2026},
volume = {7},
number = {11},
pages = {206--216},
doi = {10.70080/2790-7937.1091}
}
EUVIMED