Seismic Load Analysis of a Laboratory Building Using the Equivalent Static Method
Materials and Structures for Sustainable Infrastructure · 29.05.2026 · 1 (1) · 1-16
DOI: 10.70028/mssi.v1i1.96 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials and Structures for Sustainable Infrastructure, online erschienen am 29.05.2026. Verfasst von Bunyamin Bunyamin und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Earthquakes caused by tectonic activity are major hazards in Indonesia, requiring structures to be designed to resist seismic loads safely. This study evaluates the seismic performance of a laboratory building based on SNI 1726:2019 using real ground motion data from the 2016 Pidie Jaya earthquake. This study uses actual Pidie Jaya earthquake records to provide a more realistic seismic evaluation of existing buildings in Aceh. This study aims to evaluate the structural safety, stability, and serviceability under seismic loading using the equivalent static analysis method. The equivalent static method was used to analyze the earthquake load, where seismic forces are represented as equivalent horizontal static forces applied at each floor level. The results indicate that the fundamental period of the structure is 0.638 seconds, which remains within the allowable limit, while the base shear forces are 886.60 kN in the X-direction and 856.80 kN in the Y-direction. The difference in base shear between the X and Y directions is caused by slight asymmetries in the structure’s mass and stiffness distribution. The maximum roof displacements at an elevation of 12.60 m are 5.381 mm in the X-direction and 5.049 mm in the Y-direction, which are still below the allowable inter-story drift limits of 7.214 mm and 6.938 mm, respectively, and significantly below the overall drift limit of 84 mm. The drift limits of 7.214 mm and 6.938 mm were determined from the allowable inter-story drift ratio of 0.5% according to SNI 1726:2019 for Risk Category II structures.
Zitieren
APA
Bunyamin, B., Mistra, G., Mubarak, A., & Muhajjir, M. (2026). Seismic Load Analysis of a Laboratory Building Using the Equivalent Static Method. Materials and Structures for Sustainable Infrastructure, 1(1), 1-16. https://doi.org/10.70028/mssi.v1i1.96
Vancouver
Bunyamin B, Mistra G, Mubarak A, Muhajjir M. Seismic Load Analysis of a Laboratory Building Using the Equivalent Static Method. Materials and Structures for Sustainable Infrastructure. 2026;1(1):1-16. doi:10.70028/mssi.v1i1.96
BibTeX
@article{Bunyamin2026,
author = {Bunyamin, Bunyamin and Mistra, Gusti and Mubarak, Azzaki and Muhajjir, Muhajjir},
title = {Seismic Load Analysis of a Laboratory Building Using the Equivalent Static Method},
journal = {Materials and Structures for Sustainable Infrastructure},
year = {2026},
volume = {1},
number = {1},
pages = {1--16},
doi = {10.70028/mssi.v1i1.96}
}