EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparative analysis of diagnostic methods for G6PD deficiency: fluorescent spot test versus quantitative methods

Kochpinchon Chansing, Wiyakan Inthararujikul, Kalaya Tachavanich, Kleebsabai Sanpakit, Jassada Buaboonnam

Journal of Hematology and Transfusion Medicine · 2025

DOI: 10.69898/jhtm.35.2025.276481 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hematology and Transfusion Medicine, 2025. Verfasst von Kochpinchon Chansing und 4 weiteren Autor:innen. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a prevalent enzymopathy with significant public health implications. This study compares the diagnostic performance of the fluorescent spot test (FST), a qualitative method, with two quantitative assays--namely, the World Health Organization (WHO)-recommended method and the Glock and McLean (G&Mc) method--to assess their reliability and applicability.

Methods

A total of 221 blood samples collected between 2009 and 2021 were analyzed. Hemolysates were prepared under controlled conditions to preserve enzyme activity. Quantitative assays measured nicotinamide adenine dinucleotide phosphate(NADPH) production using spectrophotometry, while the FST provided visual confirmation under ultraviolet light. Median G6PD activities were calculated, and the sensitivity and specificity of the FST were evaluated against activity thresholds defined by the quantitative methods.

Results

The adjusted male median G6PD activity was 12.6 IU/gHb for the WHO method and 8.8 IU/gHb for the G&Mc method. The FST exhibited high sensitivity and specificity across different thresholds, with near-perfect performance at 30% activity and above.

Conclusion

The FST is a reliable tool for field-based screening of G6PD deficiency, demonstrating robust sensitivity and specificity. Quantitative methods offer enhanced precision for detailed evaluations, supporting their complementary roles in diagnostics.

Zitieren

APA

Chansing, K., Inthararujikul, W., Tachavanich, K., Sanpakit, K., & Buaboonnam, J. (2025). Comparative analysis of diagnostic methods for G6PD deficiency: fluorescent spot test versus quantitative methods. Journal of Hematology and Transfusion Medicine. https://doi.org/10.69898/jhtm.35.2025.276481

Vancouver

Chansing K, Inthararujikul W, Tachavanich K, Sanpakit K, Buaboonnam J. Comparative analysis of diagnostic methods for G6PD deficiency: fluorescent spot test versus quantitative methods. Journal of Hematology and Transfusion Medicine. 2025. doi:10.69898/jhtm.35.2025.276481

BibTeX
@article{Chansing2025,
  author = {Chansing, Kochpinchon and Inthararujikul, Wiyakan and Tachavanich, Kalaya and Sanpakit, Kleebsabai and Buaboonnam, Jassada},
  title = {Comparative analysis of diagnostic methods for G6PD deficiency: fluorescent spot test versus quantitative methods},
  journal = {Journal of Hematology and Transfusion Medicine},
  year = {2025},
  doi = {10.69898/jhtm.35.2025.276481}
}
Kostenlos starten →