EUVIMEDEUVIMED entdecken
Crossref

Mitigating Explosive Thermal Spalling in RPC with Polypropylene Fibers: Structural Mechanisms and AI-Driven Modeling

Mohammed K. Abed, Isam M. Ali, Mohammed Salah Nasr, Ahmed Samir Naje, Anishbhai Vahora, Abul Hasan

FMDB Transactions on Sustainable Structures and Materials · 2026

DOI: 10.69888/ftssm.2026.000757 ↗

Kurz gefasst

Fachartikel in der Zeitschrift FMDB Transactions on Sustainable Structures and Materials, 2026. Verfasst von Mohammed K. Abed und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research investigates the overall mechanical and thermal performance of reactive powder concrete (RPC) subjected to elevated temperatures of 250°C, 400°C, and 600°C for soaking periods of 30 and 60 minutes. Two mixture designs were evaluated: a conventional reference matrix (Mix R) with a low water-binding ratio of 18%, and a fibre-reinforced composite containing 0.2% volume fraction of polypropylene (PP) fibres (Mix RF). Each mixture was hyperthermally stable at 250°C, with internal autoclaving favouring secondary pozzolanic reactions. Compressive losses were 2.50% for Mix R and 3.49% for Mix RF at 28 days. At 400°C, portlandite and calcium-silicate hydrate (C-S-H) gel dehydrated, decreasing compressive strength by 14.5% and 17.1%, respectively. This effect intensified after 60 minutes of soaking. The traditional matrix (Mix R) at 600°C had destructive, explosive thermal spalling and premature failure due to asymmetric internal vapour flow trapped in its ultradense microstructure. However, adding 0.2% PP fibres to Mix RF melted them, creating a continuous network of interconnected microcapillary channels that efficiently facilitated internal hydrostatic vapour flow, maintaining structural integrity and providing a controlled, progressive thermal degradation pathway for internal vapour-stress relief. By providing micro-channels for internal vapour pressure relief, 0.2% polypropylene fibres prevent explosive thermal spalling in Reactive Powder Concrete (RPC) at 600°C. The AI model also accurately predicted residual compressive strength (R2 = 0.999), suggesting that fibre dose is the most important element with a 50.2% relative contribution.

Zitieren

APA

Abed, M. K., Ali, I. M., Nasr, M. S., Naje, A. S., Vahora, A., & Hasan, A. (2026). Mitigating Explosive Thermal Spalling in RPC with Polypropylene Fibers: Structural Mechanisms and AI-Driven Modeling. FMDB Transactions on Sustainable Structures and Materials. https://doi.org/10.69888/ftssm.2026.000757

Vancouver

Abed MK, Ali IM, Nasr MS, Naje AS, Vahora A, Hasan A. Mitigating Explosive Thermal Spalling in RPC with Polypropylene Fibers: Structural Mechanisms and AI-Driven Modeling. FMDB Transactions on Sustainable Structures and Materials. 2026. doi:10.69888/ftssm.2026.000757

BibTeX
@article{Abed2026,
  author = {Abed, Mohammed K. and Ali, Isam M. and Nasr, Mohammed Salah and Naje, Ahmed Samir and Vahora, Anishbhai and Hasan, Abul},
  title = {Mitigating Explosive Thermal Spalling in RPC with Polypropylene Fibers: Structural Mechanisms and AI-Driven Modeling},
  journal = {FMDB Transactions on Sustainable Structures and Materials},
  year = {2026},
  doi = {10.69888/ftssm.2026.000757}
}
Kostenlos starten →