EUVIMEDEUVIMED entdecken
Crossref

Impact of Current Transformer Saturation in Bus-Zone Protection Power Transmission Network

Swakantik Mishra, Mohammad Ahmad

FMDB Transactions on Sustainable Intelligent Networks · 05.06.2026 · 3 (2) · 113-123

DOI: 10.69888/ftsin.2026.000707 ↗

Kurz gefasst

Fachartikel in der Zeitschrift FMDB Transactions on Sustainable Intelligent Networks, online erschienen am 05.06.2026. Verfasst von Swakantik Mishra und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study examines the harmful consequences of Current Transformer (CT) saturation in bus-zone protection systems in contemporary power transmission systems. This paper focuses on the major issue of high-magnitude fault currents, which can cause core saturation, secondary current distortion, and possible relay maloperation. In analysing these phenomena, the study uses a comprehensive dataset of 356 unique faults, including different fault types, angles of inception, and levels of remanence. The main instruments used to carry out simulation-based work comprise advanced electromagnetic transient analysis programs and mathematical relay modelling tools. These findings indicate that saturation can significantly reduce the reliability of differential protection, potentially leading to catastrophic equipment failure unless countermeasures are taken. By analysing various compensation algorithms, this paper provides insights into improving the security of bus-zone protection systems. The results emphasise the importance of saturation-detection logic for distinguishing between internal and external faults that cause Current Transformer (CT) saturation.

Zitieren

APA

Mishra, S., & Ahmad, M. (2026). Impact of Current Transformer Saturation in Bus-Zone Protection Power Transmission Network. FMDB Transactions on Sustainable Intelligent Networks, 3(2), 113-123. https://doi.org/10.69888/ftsin.2026.000707

Vancouver

Mishra S, Ahmad M. Impact of Current Transformer Saturation in Bus-Zone Protection Power Transmission Network. FMDB Transactions on Sustainable Intelligent Networks. 2026;3(2):113-123. doi:10.69888/ftsin.2026.000707

BibTeX
@article{Mishra2026,
  author = {Mishra, Swakantik and Ahmad, Mohammad},
  title = {Impact of Current Transformer Saturation in Bus-Zone Protection Power Transmission Network},
  journal = {FMDB Transactions on Sustainable Intelligent Networks},
  year = {2026},
  volume = {3},
  number = {2},
  pages = {113--123},
  doi = {10.69888/ftsin.2026.000707}
}
Kostenlos starten →