Efficient Vision Transformer Architectures for Multiclass Cardiac Condition Classification from 12-Lead Electrocardiogram Images: A Comparative Study
Artificial Intelligence in Applied Sciences · 2026
DOI: 10.69882/adba.ai.2026017 ↗Kurz gefasst
Fachartikel in der Zeitschrift Artificial Intelligence in Applied Sciences, 2026. Verfasst von Armughan Ali und 1 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Rapid and reproducible interpretation of electrocardiograms (ECGs) is essential for distinguishing acute myocardial infarction from chronic infarction patterns, rhythm abnormalities, and normal recordings. This study presents a controlled comparison of three transfer-learned Vision Transformer architectures—DeiT-Small, Swin-Tiny, and ViT-Tiny—for four-class classification of 12-lead ECG report images. A total of 3,951 images were stratified into training (n = 3, 159), validation (n = 393), and independent test (n = 399) subsets representing abnormal heartbeat, history of myocardial infarction, myocardial infarction, and normal ECG. All models were initialized with ImageNet-pretrained weights and fine-tuned under the same input resolution, augmentation policy, optimizer, and stopping criterion. Performance was assessed using accuracy, macro-precision, macro-recall, macro-F1 score, parameter count, floating-point operations, and inference latency. DeiT-Small achieved the highest macro-F1 score (0.9971) with an accuracy of 0.9975, while ViT-Tiny reached the same accuracy and a macro-F1 score of 0.9969 using only 5.53 million parameters, 2.1493 GFLOPs, and 0.1275 ms per image. Swin-Tiny remained accurate (0.9825) but required the greatest computational cost. The DeiT-Small confusion matrix contained a single error, in which one normal ECG was assigned to the history-of-myocardial-infarction class. These findings indicate that compact global-attention models can retain near-perfect internal discrimination while substantially reducing computational demand. Nevertheless, patient-independent and multi-center external validation is required before clinical use.
Zitieren
APA
Ali, A., & Ganie, S. M. (2026). Efficient Vision Transformer Architectures for Multiclass Cardiac Condition Classification from 12-Lead Electrocardiogram Images: A Comparative Study. Artificial Intelligence in Applied Sciences. https://doi.org/10.69882/adba.ai.2026017
Vancouver
Ali A, Ganie SM. Efficient Vision Transformer Architectures for Multiclass Cardiac Condition Classification from 12-Lead Electrocardiogram Images: A Comparative Study. Artificial Intelligence in Applied Sciences. 2026. doi:10.69882/adba.ai.2026017
BibTeX
@article{Ali2026,
author = {Ali, Armughan and Ganie, Shahid Mohammad},
title = {Efficient Vision Transformer Architectures for Multiclass Cardiac Condition Classification from 12-Lead Electrocardiogram Images: A Comparative Study},
journal = {Artificial Intelligence in Applied Sciences},
year = {2026},
doi = {10.69882/adba.ai.2026017}
}
EUVIMED