Operação de sistema HVDC em condições de contingência em uma empresa de transmissão na região Norte do Brasil
Revista ft · 20.07.2026 · 30 (160) · 01-33
DOI: 10.69849/x7xr3931 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revista ft, online erschienen am 20.07.2026. Verfasst von Anderson Bitencourt da Silva und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The operation of High-Voltage Direct Current (HVDC) systems under contingency conditions constitutes a critical field for electrical engineering and transmission utilities, particularly in the Northern region of Brazil, where transmission projects cross the Amazon rainforest and face unique logistical challenges. This study aims to analyze the operation of HVDC systems under contingency conditions in the context of transmission companies operating in Northern Brazil, considering the technical, logistical, and regulatory dimensions. This applied research, based on a qualitative approach, adopts bibliographic research, documentary research, and a case study of the HVDC system of the Madeira River Complex as its methodological procedures. The study examines the principles of HVDC technology (LCC and VSC), the operational configuration of the Madeira River system, the contingency types established in Operation Instruction IO-OC.6MD issued by the National Electric System Operator (ONS), the protection and control mechanisms (particularly the Master Control system with its runup and runback functions), the logistical challenges associated with transmission line restoration in the Amazon environment, and the regulatory aspects related to the Variable Unavailability Portion (PVI), governed by ANEEL Normative Resolutions No. 729/2016 and No. 906/2020. The results demonstrate that contingencies in LCC-HVDC systems, particularly commutation failures and transmission tower collapses, require distinct response times. While the former can be autonomously restored within milliseconds, the latter demand extended restoration periods that may last for several months under Amazonian conditions. The Master Control system operates as a higher-level hierarchical controller, coordinating power redistribution (runup) and generation reduction (runback), thereby minimizing system-wide impacts. However, the findings reveal a tension between the regulatory requirements for system availability, materialized through the application of the PVI, and the logistical and technical constraints of the Northern region, particularly regarding the characterization of force majeure or unforeseeable events under extreme conditions. It is concluded that, although the regulatory framework and the operational procedures established by the ONS and ANEEL provide robust guidelines for contingency operation, the application of the availability incentive model requires adjustments to reflect the specific characteristics of the Amazon region. Therefore, further studies integrating dynamic simulations and quantitative analyses of actual system unavailability are recommended.
Zitieren
APA
Silva, A. B. D., & Araujo, J. M. (2026). Operação de sistema HVDC em condições de contingência em uma empresa de transmissão na região Norte do Brasil. Revista ft, 30(160), 01-33. https://doi.org/10.69849/x7xr3931
Vancouver
Silva ABD, Araujo JM. Operação de sistema HVDC em condições de contingência em uma empresa de transmissão na região Norte do Brasil. Revista ft. 2026;30(160):01-33. doi:10.69849/x7xr3931
BibTeX
@article{Silva2026,
author = {Silva, Anderson Bitencourt da and Araujo, Josiel Moreira},
title = {Operação de sistema HVDC em condições de contingência em uma empresa de transmissão na região Norte do Brasil},
journal = {Revista ft},
year = {2026},
volume = {30},
number = {160},
pages = {01--33},
doi = {10.69849/x7xr3931}
}
EUVIMED