Abstract (Originalsprache)

This article analyzes the energy and economic feasibility of modernizing HVAC (Heating, Ventilation, and Air Conditioning) systems in industrial environments located in hot and humid climate regions, such as the city of Ilhéus, Bahia. The research is based on literature reviews combined with a theoretical-quantitative case study, using as a baseline scenario a 600 m² industrial warehouse with a calculated thermal load of 144.3 kW. The methodology includes surveying efficiency indices such as COP (Coefficient of Performance), CRPI (Cooling Performance Index), and SEER (Seasonal Energy Efficiency Ratio) of conventional and modern systems with inverter compressors. It also proposes the integration of IoT (Internet of Things) devices for monitoring, annual energy consumption calculation (kWh), payback analysis, and thermal evaluation through WBGT (Wet Bulb Globe Temperature Index) according to NR-15 standards. The obtained results demonstrate that replacing single-stage compressors with inverter systems, combined with the use of frequency inverters and heat recovery units, promotes a 37.77% reduction in annual electricity consumption, decreasing from 185.5 MWh to 115.44 MWh, with a difference of 70.08 MWh and savings of approximately R$ 66,557 per year. The simple payback period is calculated at 7 years and 7 months, while the discounted payback, considering currency depreciation and an annual interest rate of 8%, is approximately 12 years and 2 months. From a thermal-occupational perspective, the modern system reduces the WBGT index from 24.2 °C to 20.5 °C, ensuring compliance with Annex III of NR-15. This adjustment significantly improves the quality of the work environment, contributing to workers’ health and productivity. It is concluded that modernization is technically and economically feasible for industries located in tropical climate regions.

Zitieren

APA

Behrmann, V. S., Krause, M. O., Pires, J. C. M., & Lins, I. D. O. (2026). Análise da viabilidade energética de sistemas HVAC em localidades de âmbito industrial. Revista ft, 30(158), 01-26. https://doi.org/10.69849/wfj2q861

Vancouver

Behrmann VS, Krause MO, Pires JCM, Lins IDO. Análise da viabilidade energética de sistemas HVAC em localidades de âmbito industrial. Revista ft. 2026;30(158):01-26. doi:10.69849/wfj2q861

BibTeX
@article{Behrmann2026,
  author = {Behrmann, Vinicius Silva and Krause, Marcelo O’Donnell and Pires, José Carlos Mendes and Lins, Ittana de Oliveira},
  title = {Análise da viabilidade energética de sistemas HVAC em localidades de âmbito industrial},
  journal = {Revista ft},
  year = {2026},
  volume = {30},
  number = {158},
  pages = {01--26},
  doi = {10.69849/wfj2q861}
}
Kostenlos starten →