Artroplastia: fatores associados à falha precoce do implante
Revista ft · 31.10.2026 · 30 (163) · 01-20
DOI: 10.69849/va3xh605 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revista ft, online erschienen am 31.10.2026. Verfasst von Lucas Fernando Murer und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To analyze the main factors associated with early implant failure in arthroplasty, considering clinical implications and strategies to prevent complications and improve prosthetic survival.
Methods
An integrative literature review was conducted using the PubMed, SciELO, Revista Brasileira de Ortopedia, NIH, Medscape, and Google Scholar databases. Studies published between 2019 and 2026 in Portuguese and English were included, using the keywords "arthroplasty," "implant failure," "early implant failure," "complications," and "risk factors." After applying eligibility and exclusion criteria, 35 articles comprised the final sample.
Results
Early failure was characterized primarily by loss of fixation, instability, or aseptic loosening within the first year post-surgery. Associated factors included periprosthetic infection, inadequate bone quality, incorrect implant positioning, early mechanical overload, and low primary stability. Male gender, higher functional demand, and the presence of pathogens that are difficult to eradicate were also associated with failure.
Conclusion
Early implant failure in arthroplasty has a multifactorial etiology involving biological, mechanical, technical, and clinical aspects. Rigorous surgical planning, appropriate implant selection, and early identification of risk factors are essential to reduce complications, avoid revision surgeries, and improve clinical outcomes.
Zitieren
APA
Murer, L. F., Rocha, A. M. F., Jardim, C. C., Rodrigues, J. R. M., & Filho, I. G. C. (2026). Artroplastia: fatores associados à falha precoce do implante. Revista ft, 30(163), 01-20. https://doi.org/10.69849/va3xh605
Vancouver
Murer LF, Rocha AMF, Jardim CC, Rodrigues JRM, Filho IGC. Artroplastia: fatores associados à falha precoce do implante. Revista ft. 2026;30(163):01-20. doi:10.69849/va3xh605
BibTeX
@article{Murer2026,
author = {Murer, Lucas Fernando and Rocha, Amom Mendes Fernandes and Jardim, Clovison Carvalho and Rodrigues, Jhonata Raimundo Martins and Filho, Idevaldo Galvão Costa},
title = {Artroplastia: fatores associados à falha precoce do implante},
journal = {Revista ft},
year = {2026},
volume = {30},
number = {163},
pages = {01--20},
doi = {10.69849/va3xh605}
}