Formação de rouge em equipamentos farmacêuticos de aço inoxidável: análise causal e plano de controle preventivo em ambientes de produção industrial
Revista ft · 08.06.2026 · 30 (159) · 01-11
DOI: 10.69849/hgpc1t49 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revista ft, online erschienen am 08.06.2026. Verfasst von Adriano Santos da Silva und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The formation of rouge on stainless steel equipment used in pharmaceutical processes is a recurring phenomenon that can compromise product integrity, process reliability, and regulatory compliance. This study presents a case of rouge occurrence in 316L stainless steel process tanks, analyzing its potential causes, formation mechanisms, and control strategies. The investigation identified the presence of Type 1 rouge, characterized by localized and easily removable deposits, with its origin primarily associated with the quality of the steam and process water system. The analysis demonstrated that the degradation of the steel's passive layer, intensified by thermal cycling and the presence of salts, was an aggravating factor. As a result, a preventive maintenance plan was developed and implemented, including the optimization of the chemical passivation process with phosphoric and citric acid (CIP-200) and the definition of an inspection and treatment frequency. It is concluded that a structured maintenance plan, focused on preventive actions and surface integrity monitoring, is effective in controlling rouge formation, reducing the risk of recurrence, and ensuring the reliability of critical equipment.
Zitieren
APA
Silva, A. S. D., Oliveira, D. D. D., Silva, J. R. V. D., & Moura, T. N. D. (2026). Formação de rouge em equipamentos farmacêuticos de aço inoxidável: análise causal e plano de controle preventivo em ambientes de produção industrial. Revista ft, 30(159), 01-11. https://doi.org/10.69849/hgpc1t49
Vancouver
Silva ASD, Oliveira DDD, Silva JRVD, Moura TND. Formação de rouge em equipamentos farmacêuticos de aço inoxidável: análise causal e plano de controle preventivo em ambientes de produção industrial. Revista ft. 2026;30(159):01-11. doi:10.69849/hgpc1t49
BibTeX
@article{Silva2026,
author = {Silva, Adriano Santos da and Oliveira, Douglas Damasceno de and Silva, João Rafael Vieira da and Moura, Telma Nagano de},
title = {Formação de rouge em equipamentos farmacêuticos de aço inoxidável: análise causal e plano de controle preventivo em ambientes de produção industrial},
journal = {Revista ft},
year = {2026},
volume = {30},
number = {159},
pages = {01--11},
doi = {10.69849/hgpc1t49}
}
EUVIMED