Influence of Shear-Wall Configuration on Ground-Floor Column Design and Material Quantities in a 12-Storey Reinforced Concrete Building
Scientific Journal of Engineering, and Technology · 17.11.2026 · 3 (2) · 196-224
DOI: 10.69739/sjet.v3i2.2546 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scientific Journal of Engineering, and Technology, online erschienen am 17.11.2026. Verfasst von Muy Chheng Moeurn und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Shear walls can be utilized to enhance the lateral strength of tall buildings; however, their arrangement can also have an effect on gravity load demands on the ground floor columns. This study sought to conduct an analysis to compare column demands and material quantities for four different types of shear wall arrangements in a 12-story reinforced concrete structure in Cambodia with four configurations of shear walls: without additional walls (M1), core walls (M2), perimeter walls (M3), and combined walls (M4). The three-dimensional linear elastic models were analyzed in Autodesk Robot Structural Analysis Professional 2021 using the factored gravity load combination of 1.2DL + 1.6LL. Four important cases of ground-floor columns (GFC13 in M1, M2, and M3, and GFC23 in M3) were then evaluated for slenderness, moment magnification, P-M interaction, and shear using ACI 318-08 guidelines. Compared to the reference model, the combined walls model decreased the column concrete volume from 50.63 m³ to 40.36 m³ (20.3%) and column steel reinforcement from 10.75 t to 9.65 t (10.2%). But such reductions cannot be made solely based on axial capacity since both reduced 300 x 300 mm column GFC23 in M3 fails the P-M check (Mc/ϕMn ≈ 2.1) and GFC13 in M3 has a very small amount of moment capacity (≈ 0.96), while other reduced columns have not been tested for that. For practicing engineers, walls adjacent to heavily loaded columns reduce their load locally, so it is useful to take advantage of the pattern of walls to determine which columns are to be checked for reductions; all reductions must go along with slenderness and P-M tests and combined wind/seismic forces. The stated reductions are not verified design savings
Zitieren
APA
Moeurn, M. C., & Sambo, P. (2026). Influence of Shear-Wall Configuration on Ground-Floor Column Design and Material Quantities in a 12-Storey Reinforced Concrete Building. Scientific Journal of Engineering, and Technology, 3(2), 196-224. https://doi.org/10.69739/sjet.v3i2.2546
Vancouver
Moeurn MC, Sambo P. Influence of Shear-Wall Configuration on Ground-Floor Column Design and Material Quantities in a 12-Storey Reinforced Concrete Building. Scientific Journal of Engineering, and Technology. 2026;3(2):196-224. doi:10.69739/sjet.v3i2.2546
BibTeX
@article{Moeurn2026,
author = {Moeurn, Muy Chheng and Sambo, Phok},
title = {Influence of Shear-Wall Configuration on Ground-Floor Column Design and Material Quantities in a 12-Storey Reinforced Concrete Building},
journal = {Scientific Journal of Engineering, and Technology},
year = {2026},
volume = {3},
number = {2},
pages = {196--224},
doi = {10.69739/sjet.v3i2.2546}
}
EUVIMED