A parametric analysis of the earth air heat exchangers' thermal efficiency and their effect on surrounding soil over time
Journal of Applied Engineering Science and Technology · 12.04.2025 · 5 (1)
DOI: 10.69717/jaest.v5.i1.111 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Engineering Science and Technology, online erschienen am 12.04.2025. Verfasst von Yousra Boutera und 6 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Earth Air Heat Exchanger (EAHE) system is widely regarded as an efficient and sustainable solution, minimizing the consumption of energy and enhancing indoor thermal comfort. This study seeks to conduct a detailed analysis of the parameters that affect the performance of EAHE systems, including the surrounding soil, climatic conditions, and time variations. A semi analytical numerical model was used and verified with existing literature data. Key parameters such as air velocity, operational periods, and soil thermal conductivity were investigated for their effect on the performance of the EAHE and the surrounding soil. The findings revealed that the model provided predictions that strongly agreed with experimental results, with only a 2.3% error margin. The study found that EAHE performance is predominantly influenced by higher soil conductivity and lower airflow velocity. In contrast, the duration of operation had minimal effect on the outlet air temperature, which increased by just 1 °C over 48 h compared to the 1st h. Lastly, the cooling of the surrounding atmosphere was identified as a key factor in enhancing the exchanger's efficiency, as it helps cool the soil after extended operation, thus restoring its cooling ability. Highlights EAHE outlet temp rose only 1 °C after 48 h continuous operation. Higher soil conductivity enhances heat transfer and cooling. Increased air velocity reduces heat exchange and cooling effect. Soil heats up over time, reducing EAHE performance without rest. Model was validated with just 2.3% error vs. experimental data.
Zitieren
APA
Boutera, Y., Boultif, N., Moummi, N., Beldjani, C., Kethiri, M. A., SM, S. M., & Müslüm, A. (2025). A parametric analysis of the earth air heat exchangers' thermal efficiency and their effect on surrounding soil over time. Journal of Applied Engineering Science and Technology, 5(1). https://doi.org/10.69717/jaest.v5.i1.111
Vancouver
Boutera Y, Boultif N, Moummi N, Beldjani C, Kethiri MA, SM SM, et al. A parametric analysis of the earth air heat exchangers' thermal efficiency and their effect on surrounding soil over time. Journal of Applied Engineering Science and Technology. 2025;5(1). doi:10.69717/jaest.v5.i1.111
BibTeX
@article{Boutera2025,
author = {Boutera, Yousra and Boultif, Nora and Moummi, Noureddine and Beldjani, Charafeddine and Kethiri, Mohamed Aymen and SM, Saleh Momen and Müslüm, Arıcı},
title = {A parametric analysis of the earth air heat exchangers' thermal efficiency and their effect on surrounding soil over time},
journal = {Journal of Applied Engineering Science and Technology},
year = {2025},
volume = {5},
number = {1},
doi = {10.69717/jaest.v5.i1.111}
}
EUVIMED