EUVIMEDEUVIMED entdecken
Crossref

Radiation Shielding Performance of Barium Sulfate–Cement Composite for Diagnostic X-Ray Applications: Experimental Measurements and Comparisons with Monte Carlo Studies

Zedan Alsnosi

Razi Medical Journal · 30.08.2026

DOI: 10.69667/rmj.26313 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Razi Medical Journal, online erschienen am 10.08.2026. Verfasst von Zedan Alsnosi.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing demand for environmentally sustainable radiation shielding materials has stimulated significant research into alternatives to conventional lead-based protection systems. Although lead remains the most widely used shielding material in diagnostic radiology, its toxicity, environmental hazards, and disposal challenges have encouraged the development of safer substitutes. In the pre-sent study, a barium sulfate (BaSO₄)–cement composite was investigated as a potential lead-free shielding material for diagnostic X-ray applications. Composite specimens containing 50 wt.% Ba-SO₄ were fabricated with thicknesses of 0.2 cm, 0.6 cm, and 1.0 cm and exposed to diagnostic X-ray beams generated at 46 kVp and 70 kVp. Transmitted radiation doses were measured using a cali-brated Geiger–Müller detection system under controlled irradiation conditions. The results demon-strated a substantial reduction in transmitted radiation intensity with increasing composite thick-ness. At 70 kVp, attenuation efficiency exceeded 90% for the 1.0 cm specimen, while near-complete attenuation was observed at 46 kVp. The measured attenuation trends were compared with findings reported in published Monte Carlo investigations employing EGSnrc, MCNP, and Geant4 radiation transport codes. Strong agreement was observed between the experimental attenuation behavior and previously reported computational predictions for barium-containing shielding materials. The enhanced attenuation performance was attributed to the high atomic number of barium and the in-creased probability of photoelectric absorption within the diagnostic energy range. The findings indi-cate that BaSO₄–cement composites represent a promising, environmentally friendly, and economi-cally viable alternative to conventional lead shielding for diagnostic radiology facilities. The combi-nation of effective attenuation performance, non-toxicity, structural compatibility, and potential uti-lization of locally available barite resources supports further development of these materials for practical radiation protection applications.

Zitieren

APA

Alsnosi, Z. (2026). Radiation Shielding Performance of Barium Sulfate–Cement Composite for Diagnostic X-Ray Applications: Experimental Measurements and Comparisons with Monte Carlo Studies. Razi Medical Journal. https://doi.org/10.69667/rmj.26313

Vancouver

Alsnosi Z. Radiation Shielding Performance of Barium Sulfate–Cement Composite for Diagnostic X-Ray Applications: Experimental Measurements and Comparisons with Monte Carlo Studies. Razi Medical Journal. 2026. doi:10.69667/rmj.26313

BibTeX
@article{Alsnosi2026,
  author = {Alsnosi, Zedan},
  title = {Radiation Shielding Performance of Barium Sulfate–Cement Composite for Diagnostic X-Ray Applications: Experimental Measurements and Comparisons with Monte Carlo Studies},
  journal = {Razi Medical Journal},
  year = {2026},
  doi = {10.69667/rmj.26313}
}
Kostenlos starten →