Assessment of Wall and Roof Insulation Thickness on HVAC Load Reduction Using HAP Simulation in a Mid-Rise Residential Building in Kabul

ABDUL RAHMAN ERFAN, MOHAMMAD MUSTAFA AKBARI

Kabul Polytechnic University International Journal of Engineering & Technology · 22.08.2026 · 6 (1) · 77-94

DOI: 10.68924/dprt7t91 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Kabul Polytechnic University International Journal of Engineering & Technology, online erschienen am 22.08.2026. Verfasst von ABDUL RAHMAN ERFAN und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Kabul's semi-arid continental climate, residential buildings have high heating and cooling energy demands because of poor insulation and envelope performance. In this study, the HVAC load of a typical mid-rise residential building in Ahmad Shah Baba Mena, Kabul, is evaluated in relation to the thickness of the insulation on the roof and the exterior walls. The Hourly Analysis Program (HAP) was used to simulate four different scenarios: a baseline model without insulation and three cases where Expanded Polystyrene (EPS) insulation was applied to the roof and external walls at thicknesses of 5 cm, 7.5 cm, and 10 cm. With four floors, three conditioned residential levels, and one unconditioned parking level, the case study building has a total conditioned area of 356.7 m². According to simulation results, thermal insulation dramatically lowers energy use, particularly for heating. In comparison to the uninsulated baseline, heating loads were reduced by roughly 39%, 41%, and 43%, respectively, when 5 cm, 7.5 cm, and 10 cm of EPS insulation were applied to the envelope. Cooling load reductions were less pronounced. This study provides useful, fact-based advice for maximizing passive envelope performance in Kabul's residential sector by assessing the effects of both wall and roof insulation. The results back up the use of moderate insulation thicknesses (7.5–10 cm) in local building design to strike a balance between cost and energy efficiency.

Zitieren

APA

ERFAN, A. R., & AKBARI, M. M. (2026). Assessment of Wall and Roof Insulation Thickness on HVAC Load Reduction Using HAP Simulation in a Mid-Rise Residential Building in Kabul. Kabul Polytechnic University International Journal of Engineering & Technology, 6(1), 77-94. https://doi.org/10.68924/dprt7t91

Vancouver

ERFAN AR, AKBARI MM. Assessment of Wall and Roof Insulation Thickness on HVAC Load Reduction Using HAP Simulation in a Mid-Rise Residential Building in Kabul. Kabul Polytechnic University International Journal of Engineering & Technology. 2026;6(1):77-94. doi:10.68924/dprt7t91

BibTeX
@article{ERFAN2026,
  author = {ERFAN, ABDUL RAHMAN and AKBARI, MOHAMMAD MUSTAFA},
  title = {Assessment of Wall and Roof Insulation Thickness on HVAC Load Reduction Using HAP Simulation in a Mid-Rise Residential Building in Kabul},
  journal = {Kabul Polytechnic University International Journal of Engineering & Technology},
  year = {2026},
  volume = {6},
  number = {1},
  pages = {77--94},
  doi = {10.68924/dprt7t91}
}
Kostenlos starten →