EUVIMEDEUVIMED entdecken
Crossref

Wpływ usztywnienia połączenia płatew–krokiew konstrukcji wsporczej paneli PV w świetle badań doświadczalnych w skali naturalnej

Andrzej Wojtycki, Bartosz Majchrzak, Arkadiusz Ryciak, Jadwiga Fangrat, Małgorzata Wydra, Wojciech Kubissa

Inżynier Budownictwa · 2026

DOI: 10.68502/ib.2026.06.17 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Inżynier Budownictwa, 2026. Verfasst von Andrzej Wojtycki und 5 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents a comparative analysis of experimental results for two typical photovoltaic panel support structures constructed from prefabricated, thin-walled, open-section steel elements. These structures were very similar in dimension and materials. They were also subjected to identical loads, both in terms of magnitude and application method. The only difference between the models tested was the method of constructing the purlin-rafter connections. The first structure uses a common quasi-articulated connection, i.e. the adjacent shelves of the connected sections are screwed together with a single screw. The second one featured an additional short angle connecting the rafter and purlin webs, providing fork-shaped support in accordance with the requirements of the [1]. The applied load, simulating the effect of climate loads, was applied in stages, and the structure’s performance was documented by recording displacements at 15 characteristic measurement points. Comparison of the results revealed a significant advantage for the structure with additional stiffening elements at the purlin-rafter joints: a reduction of element displacements by over 80% and a general increase in the local and global load-bearing capacity of the entire structure. Stiffening the joints and reducing their flexibility allowed for the co-operation of the shield created by the photovoltaic panels, simulated in the study by substitute wooden panel elements. The resulting shield diaphragm actively counteracts purlin buckling, causes global equalization of internal forces, reduces the entire system’s susceptibility to warping and stability loss, and ultimately translates into a significantly greater load-bearing capacity of the structure.

Zitieren

APA

Wojtycki, A., Majchrzak, B., Ryciak, A., Fangrat, J., Wydra, M., & Kubissa, W. (2026). Wpływ usztywnienia połączenia płatew–krokiew konstrukcji wsporczej paneli PV w świetle badań doświadczalnych w skali naturalnej. Inżynier Budownictwa. https://doi.org/10.68502/ib.2026.06.17

Vancouver

Wojtycki A, Majchrzak B, Ryciak A, Fangrat J, Wydra M, Kubissa W. Wpływ usztywnienia połączenia płatew–krokiew konstrukcji wsporczej paneli PV w świetle badań doświadczalnych w skali naturalnej. Inżynier Budownictwa. 2026. doi:10.68502/ib.2026.06.17

BibTeX
@article{Wojtycki2026,
  author = {Wojtycki, Andrzej and Majchrzak, Bartosz and Ryciak, Arkadiusz and Fangrat, Jadwiga and Wydra, Małgorzata and Kubissa, Wojciech},
  title = {Wpływ usztywnienia połączenia płatew–krokiew konstrukcji wsporczej paneli PV w świetle badań doświadczalnych w skali naturalnej},
  journal = {Inżynier Budownictwa},
  year = {2026},
  doi = {10.68502/ib.2026.06.17}
}
Kostenlos starten →