EUVIMEDEUVIMED entdecken
Crossref

Comparison Between Multiplex Real-Time Polymerase Chain Reaction and GeneXpert MTB/RIF in Detection of Mycobacterium Tuberculosis Complex in Pleural Fluid

Fahmida Hoque, S M Nakibul Mazed, Kabirul Hasan Bin Rakib, Shirin Tarafder

Jamalpur Medical Journal · 01.01.2025 · 2 (1) · 7-12

DOI: 10.68348/jpmj.48 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jamalpur Medical Journal, online erschienen am 01.01.2025. Verfasst von Fahmida Hoque und 3 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Tuberculosis (TB) continues to be the most common infectious cause of mortality worldwide. In Bangladesh, extrapulmonary TB (EPTB) accounts for 15–19% of all TB cases. Among them, pleural TB is one of the most common forms of EPTB. The diagnosis of pleural TB is difficult due to its paucibacillary nature and uneven distribution. Again, nontuberculous mycobacteria (NTM) can cause infections resembling pleural TB. Conventional diagnostic methods like microscopy and culture show low sensitivity and specificity. Nucleic Acid Amplification Tests (NAATs) are molecular methods that have improved the diagnosis of EPTB. Among the NAATs, GeneXpert MTB/RIF is the most commonly used method for diagnosis of EPTB worldwide. Another advanced molecular NAAT, Multiplex Real-Time Polymerase Chain Reaction (Multiplex rtPCR), that targets separate genes for both MTBC and NTM, can detect MTBC in the pleural fluid with high sensitivity and specificity. It can also detect NTM and differentiate it from MTBC, which can’t be obtained by GeneXpert MTB/RIF. The aim of the study was to compare the diagnostic efficiency of Multiplex rtPCR with GeneXpert MTB/RIF.

Methods

A total of 26 pleural fluid samples of suspected pleural TB cases that were sent to the Department of Microbiology and Immunology, Bangladesh Medical University (BMU), and the National Tuberculosis Reference Laboratory (NTRL), Dhaka, were included in the study, fulfilling the inclusion criteria. Multiplex real-time polymerase chain reaction (PCR), GeneXpert MTB/RIF, culture, and microscopy were performed. Ethical clearance was taken from the Institutional Review Board, BSMMU. Informed written consent was taken from patients in a predesigned consent form.

Results

Among 26 samples, 8 (30.8%) samples were tested positive for MTBC by GeneXpert MTB/RIF, whereas 11 (42.3%) were MTBC positive and 1 (3.8%) was NTM positive by Multiplex rtPCR. The sensitivity and specificity of GeneXpert MTB/RIF were 100% and 75%, respectively, and of Multiplex rtPCR were 100% and 62.5%, respectively.

Conclusion

Multiplex rtPCR increases the detection rate of both MTBC and NTM in suspected pleural TB cases simultaneously, which can’t be achieved solely by microscopy, culture, or GeneXpert MTB/RIF.

Zitieren

APA

Hoque, F., Mazed, S. M. N., Rakib, K. H. B., & Tarafder, S. (2025). Comparison Between Multiplex Real-Time Polymerase Chain Reaction and GeneXpert MTB/RIF in Detection of Mycobacterium Tuberculosis Complex in Pleural Fluid. Jamalpur Medical Journal, 2(1), 7-12. https://doi.org/10.68348/jpmj.48

Vancouver

Hoque F, Mazed SMN, Rakib KHB, Tarafder S. Comparison Between Multiplex Real-Time Polymerase Chain Reaction and GeneXpert MTB/RIF in Detection of Mycobacterium Tuberculosis Complex in Pleural Fluid. Jamalpur Medical Journal. 2025;2(1):7-12. doi:10.68348/jpmj.48

BibTeX
@article{Hoque2025,
  author = {Hoque, Fahmida and Mazed, S M Nakibul and Rakib, Kabirul Hasan Bin and Tarafder, Shirin},
  title = {Comparison Between Multiplex Real-Time Polymerase Chain Reaction and GeneXpert MTB/RIF in Detection of Mycobacterium Tuberculosis Complex in Pleural Fluid},
  journal = {Jamalpur Medical Journal},
  year = {2025},
  volume = {2},
  number = {1},
  pages = {7--12},
  doi = {10.68348/jpmj.48}
}
Kostenlos starten →