EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY-NC-ND 4.0

Fuzzy and Neuro-Fuzzy Models for Coronary Artery Disease Detection: A Systematic Review of Development, Validation and Risk of Bias in Open-Access Literature

Shehu Muhammad, Timothy Moses, Mukthar Muhammad, Mahmud Ahmad Bamanga

Nigerian Journal of Operations Research · 23.11.2026 · 3 (4) · 46-67

DOI: 10.67868/nijor/0304.031 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Nigerian Journal of Operations Research, online erschienen am 23.11.2026. Verfasst von Shehu Muhammad und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fuzzy and neuro-fuzzy models are often proposed for the detection of coronary artery disease (CAD), because their reasoning is expressed as rules that clinicians can read. How these models are developed and validated, and how much risk of bias they carry, has not been appraised systematically. We searched PubMed and OpenAlex from inception to 3 October 2026. Screening, data extraction and risk of bias assessment with PROBAST applied predefined rules and were checked by the research team, with every decision and its reason recorded; no second reviewer repeated these steps independently. Full texts were limited to those available in open access. Of 1,925 unique records, 794 were sought in full text, and 132 could be assessed. In total, 62 reports were included: 26 used ANFIS or another neuro-fuzzy network and 24 a fuzzy rule-based system. Of these, 28 used the UCI heart disease data, and 12 did not clearly report their data. Only 1 report validated its model in a separate cohort, 3 reported an area under the ROC curve, and 1 reported calibration. In all, 61 of the 62 models were at high risk of bias, in every case including the analysis domain, and one was unclear. Reported accuracies of up to 99.66% came from internal validation, and no meta-analysis was possible. In the open-access literature, fuzzy and neuro-fuzzy models for CAD are not ready for clinical use. Because 61 of the 62 models (98.4%) did not report calibration, their predicted probabilities cannot yet support threshold-based triage or the allocation of scarce diagnostic resources. Future studies should use clinical cohorts of adequate size, report the full rule base, assess calibration, and test their models in new populations.

Zitieren

APA

Muhammad, S., Moses, T., Muhammad, M., & Bamanga, M. A. (2026). Fuzzy and Neuro-Fuzzy Models for Coronary Artery Disease Detection: A Systematic Review of Development, Validation and Risk of Bias in Open-Access Literature. Nigerian Journal of Operations Research, 3(4), 46-67. https://doi.org/10.67868/nijor/0304.031

Vancouver

Muhammad S, Moses T, Muhammad M, Bamanga MA. Fuzzy and Neuro-Fuzzy Models for Coronary Artery Disease Detection: A Systematic Review of Development, Validation and Risk of Bias in Open-Access Literature. Nigerian Journal of Operations Research. 2026;3(4):46-67. doi:10.67868/nijor/0304.031

BibTeX
@article{Muhammad2026,
  author = {Muhammad, Shehu and Moses, Timothy and Muhammad, Mukthar and Bamanga, Mahmud Ahmad},
  title = {Fuzzy and Neuro-Fuzzy Models for Coronary Artery Disease Detection: A Systematic Review of Development, Validation and Risk of Bias in Open-Access Literature},
  journal = {Nigerian Journal of Operations Research},
  year = {2026},
  volume = {3},
  number = {4},
  pages = {46--67},
  doi = {10.67868/nijor/0304.031}
}
Kostenlos starten →